Specifications
61
OUTPUT UNITS |
Blind Control Relay
The Blind Control Relay units are designed to directly drive the motors for soft furnishing components like motorised blinds,
curtains, shutters and awnings. The relay unit can be easily installed in the switchboard or in the eld in the optional din-rail
mount enclosure.
Designed with the installer in mind, this unit provides a easy to install module with features required to make direct motor
control safe and simple.
TECHNICAL INFORMATION
Catalogue Number L5501RBCP
C-Bus Supply Voltage 15-36V DC @ 22mA required for normal operation.
Does not provide current to the C-Bus Network
AC Input Impedance 80k @ 1kHz
Electrical Isolation 3.75kV RMS from C-Bus to mains
Max. Units per Network 80
Load Current Rating 2A (motor load)
Load Voltage Rating 24V DC, 24-240V AC
Warm Up Time 5 seconds
Network Clock Software Selectable
Network Burden Software Selectable
Class of Switch Class II
Rated Impulse Withstand Voltage 4 kV
Operating Temperature 0° to 45° C
Operating Humidity 10 to 95% RH
Dimensions (W x H x D) 36 x 93 x 63mm
Weight 250g
Mains terminals Accommodates 2 x 1.5mm2 or 1 x 2.5mm2
(2 x 15AWG or 1 x 13AWG)
Catalogue Number 5501RE
Dimensions (W x H x D) 159 x 75 x 47mm
Mounting Centres 84mm
Weight 116g
PRODUCT FEATURES
• Internally electrically interlocked directional contacts
• One, two or three button control from C-Bus switchplates or
touchscreens
• Programmable time delays (0.5 – 4.0 seconds) between
motor direction change
• Din-rail mounting or optional enclosure for eld installation
of unit
• Local manual override buttons to assist with setting end-
limits.
CATALOGUE NUMBER DESCRIPTION
*L5501RBCP Blind Control Relay
*5501RE Enclosure for Blind Control Relay
*Ask for availability
L5501RBCP
L5501RBCP illustrated
5501RE illustrated