³ CAUTION! Do not disturb CP-100/100D until firmware upgrade is finished!! Normally,
firmware upgrade takes about 1 minute. When upgrade is completed, CP-100/100D
automatically restarts.
9.2. Firmware Upgrade by UTP Cable
In case your CP-100/100D is not accessible via its IP address, you can perform firmware upgrade by
connecting the CP-100/100D and a PC using UTP cable. The PC should have an Ethernet interface.
This method requires a firmware-uploading program installed on PC, which can be downloadable at
CLIPCOMM’s technical support page.
Firmware upgrade by UTP cable is performed by the following procedure:
Turn-off your CP-100/100D.
Connect your CP-100/100D and PC with UTP cable. You can connect PC and “LAN” port of CP-
100/100D directly with UTP cable. Or you can configure that PC and CP-100/100D are connected
to same HUB.
Execute firmware upload program on PC. Contact techsupport website of CLIPCOMM.
Assign new firmware file and turn on your CP-100/100D with both AutoAnswer and VoIP button
pressed. Release buttons after a few seconds.
Firmware uploading begins when you press “OK” button of the firmware upload program.