Manual

9
Installation
Connection Schematic
The high speed dome camera series can be connected to various optional accessories through
the standard connector types, which simplify the cable handling and avoids possible errors. All
accessories are tested for maximum compatibility and best performance.
RS485 Cable-
The telemetric control of the device uses RS485 serial communication with half duplex
transmission technology. The transmission distance can vary, depending on cable type,
and baud rate. The following table shows maximum distances based on cable with 0,56mm
(24AWG) twisted pair:
Baud Rate Max. Distance
2400 bps 5577ft / 1700m
4800 bps 3609ft / 1100m
9600 bps 2297ft / 700m
19200 bps 1312ft / 400m
Due to environmental interfaces, such as electromagnetic and induction elds, or number of connected
devices on the RS485 bus, or using thinner than 24AWG cable, the transmission range may be less.
This dome has jumperless design,
meaning protocol, baud-rate,
and ID are to be set in OSD. The protocol
can be automatically recognized by the
system. For the rst start, please ensure
your keyboard parameters match those
shown on the initial screen (ie. protocol,
baud-rate, ID). Doing so will allow you to
enter the OSD for further settings.