6.3. CTC-1052-QT-DT35A Voice Prompts 
The Control Panel plays voice prompts on important occasions to report its condition or remind you to 
take a specific action. Information on voice prompts is provided in the chart below. 
Voice Prompt  Condition 
Release the Button 
Played once after long pressing (6 seconds) the Learn Button on the 
Control Panel to enter learning mode. 
Ready to Learn Sensor  Played once after entering learning mode 
Press Sensor Button 
Played once if no action within 10 seconds after “Ready to learn 
sensor” prompt. This prompt will repeat two times if no action. 
Press the Button to Exit 
Played once if no action after second “Press Sensor Button” prompt. 
This prompt will be repeated three times if no action continues. 
{Sensor Type} Learned 
Played in learning mode, when the button on the device or sensor is 
pressed 
We are now in normal operation mode 
Played once when the Learn Button was pressed to exit learning 
mode. 
Played once after five minutes of no action in learning mode. The 
Control Panel as returned to idle mode. 
Emergency Button/Panic Button  Played once when the sensor has been learnt into the Control Panel 
Smoke Detector  Played once when the sensor has been learnt into the Control Panel 
Heat Detector  Played once when the sensor has been learnt into the Control Panel 
Motion Sensor  Played once when the sensor has been learnt into the Control Panel 
Fall Sensor  Played once when the sensor has been learnt into the Control Panel 
Carbon Monoxide Detector  Played once when the sensor has been learnt into the Control Panel 
Door Sensor  Played once when the sensor has been learnt into the Control Panel 
Water Leak Sensor  Played once when the sensor has been learnt into the Control Panel 
Emergency call was pressed 
Played once after pressing the Help Button on the Control Panel, 
Active Button on Panic Button, WTR, Fall Sensor or DECT device. 
Emergency call in progress  Played once every 2-3 seconds during guard time 
Emergency call cancelled  Played twice when the reset button is pressed during guard time 
A fall has been detected  Played once when a fall sensor is triggered. 
Fall detection has restored, 
cancelling help call 
Played after the reception of a fall sensor’s cancel code 
Water Leak Alarm  Played when water has been detected by Water Leakage Detector 
Fire Alarm  Played when fire has been detected by Fire Alarm 
Carbon Monoxide Alarm 
Played when specific levels of carbon monoxide is detected by 
Carbon Monoxide Detector 
Power failure, check power cord  Played twice when a power failure takes place 
Power restored  Played once when power is restored 
Inactivity timer expiring, please reset 
Played once every 5 minutes during Warning Period (default 30 
minutes). After Warning Period, the Control Panel will start reporting 
to Monitoring Centre 
Inactivity timer reset  Played once when the inactivity timer has been reset 
Searching for Cell Signal  Played when cellular module is activated 
System Ready  Played when GSM registration is successful 
GSM Signal 
(One, Two, Three, Four, Five) 
Played when the Learn Button is pressed to exit Learning Mode to 
announce GSM RSSI value. 
Test Call being placed  Played when the test button is pressed. 