User's Manual
39 
absence of battery in the following cases: 
  Battery not connected 
  Battery failure.  
  When  the  battery  disconnection  lasts  for 
10-15  minutes,  CTC-1052-QT-DT35A  will 
report  to  the  Monitoring  Center  and  the 
GREEN LED will flash slowly. 
  After  the  battery  is  restored  for  10-15min, 
CTC-1052-QT-DT35A  will  send  Battery 
Restore  report  to  Monitoring  Center  and 
the GREEN LED returns to steady ON. 
5.1.5. Devices Low Battery 
  When  CTC-1052-QT-DT35A  receives  a 
battery  low  signal  from  a  particular  device, 
it  will  report  to  the  Monitoring  Center  and 
the  GREEN  LED  will  flash  rapidly  until  the 
fault condition is cleared. 
  Press the Reset Button on CTC-1052-QT-
DT35A, the LED will turn on. 
  If any device Low Battery signal is received 
again,  the  LED  will  light  up  accordingly. 
Press the Reset Button again, the LED will 
turn on. 
  After  the  faulty  battery  is  replaced,  CTC-
1052-QT-DT35A  will  immediately  send 
Battery  Restore  report  to  the  Monitoring 
Center for that particular device. 
5.1.6. Automatic Check-in Report = 
Periodic Test Call 
  When  CTC-1052-QT-DT35A  is 
programmed  to  send  a  periodical  check-in 
report,  CTC-1052-QT-DT35A  will  report  to 
the Monitoring Center accordingly. 
  The  Periodic-Check-in  Timer  will  be  reset 
whenever Programming Mode is entered. 
5.1.7. Mobility Timer 
  In  order  to  check  the  user’s  well  being,  a 
Mobility  Timer  can  be  set  by  using 
Command #44. 
  If  Mobility  Timer  is  set  as  Enabled,  a 
counting down period starts from: 
  Immediately  after  powering  up  CTC-
1052-QT-DT35A. 
  Exiting Programming Mode 
  After the pre-set Timer expires, CTC-1052-
QT-DT35A    will  emit  a  voice  prompt 
reminder  “Inactivity  timer  expiring,  please 
reset.” every 5 minutes to notify the user for 
30 minutes. 
  When the Mobility timer is not reset after 30 
minutes,  CTC-1052-QT-DT35A  will  send  a 
Mobility  Timer  Expired  report  to  the 
Monitoring Center. 
  After  CTC-1052-QT-DT35A  sends  a 
Mobility  Timer  Expired  Report,  but  the 
Mobility  timer  was  still  not  reset,  when 
reaching  next  pre-set  time,  the  CTC-1052-
QT-DT35A  will  emit  a  beep    every  5 
minutes  to  notify  the  user  for  30  minutes. 
Yet, if no reset action after 30 minutes, the 
panel  will  send  another  Mobility  Timer 
Expired report to the Monitoring center and 
the step will be repeated until Mobility timer 
is reset. 
  Mobility  Timer  can  be  reset  by  pressing 
RESET  button  once  on  CTC-1052-QT-
DT35A  or  whenever  a  movement  is 
detected  by  PIR  Detector.  CTC-1052  will 
also  play  a  voice  prompt  “Inactivity  timer 
reset.” to inform the user. 
  To disable the Mobility Timer function: 
  Set Command #44 to 00 (Disable) 
<NOTE> 
  If  no  movement  is  detected  during  preset 
mobility  time,  CTC-1052-QT-DT35A  will 
send  a  CID  event  code  641  with  a  fixed 
zone  number  071  regardless  of  the  zones 
the triggered motion detectors occupy. 
5.1.8. Country Code 
The  Phone  Number  Format  for  each  SIM  card 
may vary between different Telecom companies. 
Thus,  you  can  either  check  with  your  Telecom 
provider  or  follow  the  steps  described  below  to 
check the correct format. 
Step 1:  Remove the SIM card from SIM card 
holder on the Panel, and insert it into a 
workable mobile phone. 
Step 2:  Power  on  the  mobile  phone  and  send 
a test SMS message to another mobile 
telephone number. 
Step 3:  Once  the  test  message  is  received, 
you can then check the phone number 
format shown in the received message. 










