User's Manual
38 
5. Operation 
5.1. Idle Mode 
When  the  system  is  in  Idle  Mode,  CTC-1052-
QT-DT35A  is  ready  to  execute  the  following 
functions: 
5.1.1. Answering Incoming Phone Calls 
This  function  is  only  available  when  Command 
#31 is set as ON (factory default is OFF). 
  For an Incoming telephone call, CTC-1052-
QT-DT35A  will  emit  cycles  of  2  quick 
beeps. 
  User can answer the call either by pressing 
the  Active  button of WTR, PB, or Fall 
Sensor or  the  Help  Button  on  CTC-1052-
QT-DT35A.  Once  CTC-1052-QT-DT35A 
answers  the  call,  it  will  open  a  Two-Way 
Voice Communication. 
  You  can  use  the  following  DTMF 
commands  to  change  the 
communication type: 
DTMF (1) to TALK ONLY 
Enter  DTMF  (2)  to  open  TWO-WAY 
VOICE COMMUNICATION 
Enter DTMF (3) to LISTEN-IN ONLY  
  Enter (7) to Speaker Volume Control 
and then press (6) or (4) to increase 
or decrease the levels of speaker 
volume in the “Two-Way” 
communication mode(not in TALK 
ONLY mode). 
  Enter (8) to Microphone Sensitivity 
Control and then press (6) or (4) to 
increase or decrease the levels of 
microphone sensitivity in the “Two-
Way” communication mode. 
  If the speaker volume and microphone 
sensitivity was adjusted, the adjusted 
value will be kept for the next 
communication. 
  To  hang-up,  press  either  the Active 
button of WTR, PB, or Fall Sensor, or 
the  Reset  Button  on  CTC-1052-QT-
DT35A.  
  To  hang-up  as  the  caller,  he/she  can 
press DTMF 9 or just put the handset 
back into the base cradle. 
  30 minutes is allowed for each call. 
Auto-Answer Numbers 
The  Control  Panel  can program  up  to  20  Auto-
Answer  Numbers.  If  a  user  calls  the  Control 
Panel using an auto-answer number, the Control 
Panel will pick up the call and instantly open up 
a two-way communication with the caller. 
The  Control  Panel  will  auto-answer  calls  from 
the auto-answer numbers and are unaffected by 
Command  #31.  Please  refer  to  Command  #00, 
on how to program these numbers. 
5.1.2. AC Power Check Up  
  If  the  AC  Power  failure  is  detected  for  10 
seconds  or  longer,  the  GREEN  LED  starts 
to flash as a visual warning to the user and 
voice  prompt  “Power  failure,  check  power 
cord.”  4G/LTE  module  will  be  turned  off  to 
conserve power.  Remote Programming will 
thus  become  unavailable.  4G/LTE  module 
will only  be  turned on  when  activated from 
the Control Panel side. 
  When  AC  Power  resumes,  the  GREEN 
LED  will  turn  on  again,  and  will  voice 
prompt “Power restored.” 
  If  the  AC  Power  failure  lasts  for  an  hour, 
CTC-1052-QT-DT35A  will  send  an  AC 
Failure report to the Monitoring Center. 
  After the Power restoration lasts more than 
one  hour,  CTC-1052-QT-DT35A  will  report 
AC Restore to the Monitoring Center. 
  During  the  AC  Power  failure  period,  the 
Call-Back  function  is  automatically 
disabled. 
5.1.3. CTC-1052-QT-DT35A Low Battery 
  CTC-1052-QT-DT35A  continuously  checks 
its  own  Battery  Condition  30  minutes  after 
powering up. 
  When the low battery condition lasts for 4 - 
6 mins, CTC-1052-QT-DT35A will report to 
the Monitoring Center and the GREEN LED 
will flash slowly. 
  After  the  battery  voltage  is  restored  and 
lasts  for  12  hours,  CTC-1052-QT-DT35A 
will  send  Battery  Restore  report  to 
Monitoring  Center  and  the  GREEN  LED 
returns to steady ON. 
5.1.4. CTC-1052-QT-DT35A Battery 
Disconnection 
  CTC-1052-QT-DT35A  can  detect  the 