User's Manual
19 
CORRESPON-
DING DTMF 
CHARACTER 
COMMANDS 
ITEM  COMMAND  EXAMPLE & USAGE  DEFAULT
22# 
Reporting 
method for 
Telephone 
number 2 
FMAT2 
PROG 8744 FMAT2:0 
To set the reporting method for Telephone number 2 
3=Speech, 4=SMS CID 
3=Speech
23# 
Reporting 
method for 
Telephone 
number 3 
FMAT3 
PROG 8744 FMAT3:0 
To set the reporting method for Telephone number 3 
3=Speech, 4=SMS CID 
3=Speech
24# 
Reporting 
method for 
Telephone 
number 4 
FMAT4 
PROG 8744 FMAT4:0 
To set the reporting method for Telephone number 4 
3=Speech, 4=SMS CID 
3=Speech
31# 
Ringer 
enable for 
incoming 
calls 
ENRIN 
PROG 8744 ENRIN:0 
To enable/disable ring tone for incoming calls 
0=Disable, 1=Enable 
0 = Disable
32# 
Audible fault 
alert 
FAUTA 
PROG 8744 FAUTA:0
To enable/disable audible fault alert 
0=Disable, 1=Enable 
0 = Disable
34# 
Emergency 
button 
EMBUT 
PROG 8744 EMBUT:1
To enable/disable the Emergency button to send an 
emergency alarm report 
0=Disable, 1=Enable 
1 = Enable
35#  Silent mode  SILMO 
PROG 8744 SILMO:1
To enable/disable silent mode 
0=Silent mode On, 1=Silent mode Off 
1 = Silent 
mode Off
37# 
AC fault 
report 
ACRPT 
PROG 8744
A
CRPT:1
To enable/disable AC fault report 
0=Disable, 1=Enable 
1 = Enable
38# 
Follow-On & 
Call Back 
FOLON 
PROG 8744 FOLON:0
To set the follow-on & call back mode 
0=Follow-on (Reserved), 1=Call-back, 2=Follow-on & Call-
back 
0 = Follow-
on 
40# 
Set access 
code 
ACCES 
PROG 8744
A
CCES:1234
To change the access code for installer (4-digit) 
8744 
42# 
Guard time 
delay 
GUDTI 
PROG 8744 GUDTI:10
To set the guard time delay time for a compatible sensor 
(except Fall Sensor) 
00=Instant, 01-99=1-99 seconds 
00= instant 
reporting
43# 
Periodic test 
call 
TESTC 
PROG 8744 TESTC:DDHHMM
To set the periodic test call 
DD:00-07=0-7 Day(s) 
HH= 00-23=0-23 Hour(s) 
MM=00-59=0-59 Min(s) 
000000= Disable 
Example: PROG 8744 TESTC:012359 
01= 1 Day 
23=23 Hours 
59= 59 mins 
7 Days 
44# 
Mobility 
timer 
MOBTI 
PROG 8744 MOBTI:00 
To set the Mobility timer 
00=Disable, 01-36 =1 - 36 Hours 
00 = 
Disable
46# 
Two-way 
period 
FOLTI 
PROG 8744 FOLTI:02 
To set the duration for two-way voice communication 
period 
01-10=1-10 minutes 
10 = 
10 minutes
47#  Off-set time  OFFST 
PROG 8744 OFFST:1 
To set the off-set time 
1=1 Hour, 2=2 Hours, 3=3 Hours 
4=4 Hours, 5=8 Hours, 6=12 Hours 
1 = 
1 Hour 