User's Manual

7
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
>
>
If a 2-hour supervision period is set (SW1-off, SW2-On, SW3-off), the
RPN-99 will send the “supervision” signal every 2 hours.
SW 5 : TEST button.
When it is pressed, RPN-99 will automatically sends out a Test signal. It
can be used for Range Test.
SW 6: RESET button.
Pressing the button, the RPN-99 will do a power-on Reset and send a
“power-on check-in” signal.
z Power Supply
z A DC 12V, 800mA (minimum) power adaptor is used to power the RPN-99.
z In addition, there is a 1,600mAh x 8 Ni-mh rechargeable battery is used as a
back-up power.
z When the battery is fully charged, it can provide back-up time of 15 hours. It
takes approximately 36 hours to fully charge the battery.
z Mounting the RPN-99
z The RPN-99 comes with a mounting bracket.
z To mount the RPN-99,
z Using the two holes in the mounting bracket as a template, drill two holes on the
place of desired installation and insert the plastic dowels into these holes.
z Screw the bracket onto the site of installation, through the dowels.
z Then hang the RPN-99 on the bracket.
z Tamper protection
z The RPN-99 also features “Tamper protection” after hanging on the mounting
bracket, any attempt to remove it from the mounting bracket will trigger the
tamper switch and the RPN-99 will transmit the “Tamper active” signal
accordingly.
z Queue Buffer
z The RPN-99 has a Queue Buffer to store up to 12 signals to be transmitted.
z During transmission, the RPN-99 takes the data from the Queue Buffer
one-by-one following First-in-First-out algorithm.
z If a signal received already exists in the Queue Buffer, this signal will be ignored.