Specifications
3
Walk Test
To test whether the Relay Controller is able to communicate with the Control Panel:
Put the Control Panel into Walk Test mode.
Press the Test Button on the Relay Controller.
The Control Panel should display if the Relay Controller is within the operation range (please
refer to the operation manual of the Control Panel).
Supervision
After the Relay Controller is successfully learned in to the Control Panel, the device will
automatically transmit supervisory signal along with ON/Off status to the Control Panel at
random intervals of 30 to 50 minutes.
If the Control Panel has not received the signal from the Relay Controller for the preset period
of time, the Control Panel will indicate on its display that the particular Relay Controller is
experiencing an out-of-signal problem.
Operation
R
R
e
e
l
l
a
a
y
y
C
C
o
o
n
n
t
t
r
r
o
o
l
l
After learned into the Control Panel, the Relay Controller can be controlled via the Panel
webpage to remotely open and close the connected device or toggle between on and off
conditions.
You can also press the test button on the Relay Controller to switch ON/OFF the Relay.
Factory Reset
Factory resetting the Relay Controller will clear its memory and restore it to factory default settings.
1 Remove the Relay Controller from the Control Panel. Refer to the operation manual of your Control
Panel for details.
2 Remove power supply from the Relay Controller.
3 Press and hold the test button while supplying power to the Relay Controller.
4 Keep holding the button, then release it when LED lights up. Factory reset is complete.