Specifications

2
It is recommended to install the device in a fire resistant plastic gangbox.
Do not install the device in a metal gangbox for optimization of RF range.
Caution
All works on the device, including installation and maintenance, must be performed by a
qualified and licensed electrician.
To prevent electrical shock and/or equipment damage, disconnect electrical power at the
main fuse or circuit breaker before installation and maintenance.
Do not connect the device to loads exceeding supported load current.
Installation
Please turn off the power supply before connection. Wire the Relay according to the
instructions below or refer to the diagram for more information.
1. Remove the top cover and remove the strain relief clamp.
2. Connect the L and N terminals of the power supply to the Line and Neutral terminals of PRL
respectively through the wiring hole.
3. Depending on the device you wish to control via the Relay, select NO or NC
terminal and wire the Relay with the device to establish Normal Open or Normal
Close connection with device.
4. After completing device wiring, replace the strain relief clamp, use the wiring
buckle to manage the wires, and place the wiring buckle on the base with its gap
(opening) positioned on the left (as in the diagram below).
5. Replace the top cover. Turn on the power supply to power on the Relay Controller.
Getting Started
Step 1: Connect power supply to the Relay Controller according to the installation instructions in
previous section and power up the Relay Controller.
Step 2: Put the Control Panel into learning mode.
Step 3: Press and hold the Test button on the Relay Controller for 3 seconds to send a learn code.
Step 4: The LED will start to flash slowly, indicating that the Relay Controller is in learning mode.
Step 5: If the Control Panel receives the signal from the Relay Controller, it will display the
information accordingly. Refer to the Control Panel manual to complete the learn-in
process.
Step 6: When the Relay Controller receives acknowledgement from the Control Panel, the LED of
the Relay Controller will flash 3 times and then turn off to indicate that learning process is
completed.
<
<
N
N
O
O
T
T
E
E
>
>
After entering learning mode, the Relay Controller will not automatically leave learning
mode unlesss it receives acknowledgement from the Control Panel, or unless the Test
button is pressed.
If the Relay Controller already exists in a Control Panel system, you will need to first
remove the Relay Controller from the Control Panel before you can learn it into a different
Control Panel.