User's Manual
4
YELLOW LED ON – Other fault condition (not including AC Power Failure ).
LED OFF – System normal.
LED Flashing Sequence
:
Alarm
>
Alarm Memory
>
Panel AC failure
>
Other Fault
3. Operational Status LED (Dual Colour - Yellow & Red) (with display priority)
YELLOW LED ON - Network error
LED OFF – Network ok
LED Flashing Sequence: Network ok
>
Network error
4. Standing Base
5. Internal Buzzer
6. Ethernet Port
7. Learn/Reset Button
8. Base
9. DC Jack
For connecting the DC 12V, 1A
switching power.
10. Battery Switch
2.2. The Power Supply:
An AC power adapter is required to connect to a wall outlet. Be sure only to use an adapter with
the appropriate AC voltage rating to prevent component damage. DC 12V 1A switching power
output adaptor is generally used to power the Control Panel for standard version.
Rechargeable Battery
In addition to the adapter, there is a rechargeable battery inside the Control Panel, which
serves as a back up in case of a power failure.
During normal operation, the AC power adapter is used to supply power to the Control
Panel and at the same time recharge the battery. It takes approximately 72 hours to fully
charge the battery.
<
<
N
N
O
O
T
T
E
E
>
>
If the AC power is missing and the battery is near exhaustion, a low battery message
will be displayed and the internal siren will be disabled to conserve power.