Water
The Water device is active all the time and does not have to be armed or
disarmed. An Event Code of #154 will be reported with trigger.
Set/Unset (For Door Contact Only)
If the Door Contact is set to Set/Unset, the system will be disarmed when the
Door Contract is triggered, and armed when Door Contact is closed.
<
<
N
N
O
O
T
T
E
E
>
>
Please refer to Normal Open/Normal Close section below for further detail.
Silent Panic
If the device attribute is set as Silent Panic, when the device is activated, the
Control Panel will report a Slient Panic alarm without sounding an audible siren.
An event code of 122 will be reported.
Personal Attack
If the device attribute is set as Personal Attack, when the device is activated, the
Control Panel will activate an alarm and report an event code of 120 will be
reported.
Bypass: If Bypass is selected, the device will be deactivated. When a bypassed device
is triggered, the Control Panel will not raise alarm.
Latch Report: If Latch Report is selected, the Control Panel will send report when the
device is triggered.
Normal Open: This option is only available for Door Contact:
If Normal Open is selected, the Door Contact will be triggered when it is closed.
If Normal Open is selected, the Door Contact will be triggered when it is opened.
Group: This option is only available for Power Switch. You can assign multiple Power
Switches to a group and control the group together
<
<
N
N
O
O
T
T
E
E
>
>
To avoid accidental tamper trigger, when you are changing device batteries or moving
device locations, be sure to use the Bypass function to temporarily deactivate the
device.
6.5. Delete Device
In order to remove devices from the Control Panel, check the number boxes before the device
name, then click Delete, the selected devices will be removed.
6.6. Request Media
You can manually control the selected PIR Camera and PIR Video Camera to take a picture or
record a 10-second video clip. The requested picture and video clip can be viewed in “Captured
Event” webpage.