User's Manual
30
When the system is in any Armed mode, and the Control Panel is counting down
the Entry Delay, if a “Burglar” device is triggered, the Control Panel will not
respond.
During the Exit Delay period, if a “Burglar” device is triggered, the Control Panel
will not respond .
Away Only
When the system is in Away Arm mode, if an “Away Only” device is triggered, a
“Burglar Alarm” will be activated immediately and reported.
When the system is in any Home Arm mode, if an “Away Only” device is
triggered, the Control Panel will not respond.
During the Entry Delay or Exit Delay period, if an “Away Only” device is triggered,
the Control Panel will not respond .
Entry
When the system is in any Arm mode, if an “Entry” device is triggered, the
Control Panel will start an Entry Delay countdown timer for the user to disarm the
system.
After the delay period has expired and no correct PIN code has been entered, the
Control Panel will activate a “Burglar Alarm” and the event will be reported.
When the system is in Disarm mode, if a “Entry” is triggered, the Control Panel
will make a “ding-dong” Door Chime sound (if Door Chime function is not
disabled).
Away Entry
When the system is in Away Arm, if an “Away Entry” device is triggered, the
Control Panel will start an Entry Delay countdown timer for the user to disarm the
system.
After the delay period has expired and no correct PIN code has been entered, the
Control Panel will activate a “Burglar Alarm” and the event will be reported.
When the system is in Disarm mode, if a “Entry” is triggered, the Control Panel
will make a “ding-dong” Door Chime sound (if Door Chime function is not
disabled).
When the system is in any Home Arm mode, if an “Away Entry” device is
triggered, the Control Panel will not respond.
During the Entry Delay or Exit Delay period, if an Away Entry device is triggered,
the Control Panel will not respond
24 Hour
The 24 Hour device is active all the time and does not have to be armed or
disarmed. An Event Code of #130 will be reported with trigger.
Fire
The Fire device is active all the time and does not have to be armed or disarmed.
An Event Code of #111 will be reported with trigger.
Medical Emergency
A Medical Emergency device is active all the time and does not have to be
armed or disarmed. An Event Code of #101 will be reported with trigger.