User's Manual

83
When Carbon Monoxide Detector (CO) is triggered or
its test button
pressed.
D#1019 - AC Power Failure in the Base Station
When AC power fails for more than 10 seconds, the green LED blinks
every second.
D#1019 Base Station Low on Battery/Base Station’s Battery
Disconnected
When the Base Station is low on battery, the green LED blinks every 2
seconds.
When the Base Station’s battery is disconnected, th
e green LED blinks
every 2 seconds.
7.4. Climax CPC Dialect Event Codes
55 – Base Station Emergency
When the red help button on the Base Station is pressed.
When Pendant #1 is pressed.
When Fall Sensor is triggered or pressed.
54 - WTR Emergency
When WTR or Fall Sensor is pressed.
29 - SD Emergency
When Smoke Detector (SD) is triggered.
5
8 - Fall Emergency
When Fall Sensor is triggered.
14 - Inactivity
An inactivity code will be sent to the CMS if there is no movement
during guard time after fall detection.
21 - WTR Supervision Failure/No WTR Learnt in
When the Base Station is unable to receive a signal transmitted from a
sensor for a period preset by the supervision timer.
When the Base Station has no WTR learnt in.
19 - AC Power Failure in the Base Station
When AC power fails for more than 10 seconds, the green LED blinks
every second.
20 - AC Power Restored
When AC power is restored to the Base Station.
4
2 - Base Station Low on Battery/Base Station’s Battery
Disconnected