User's Manual
69
6.2.1.7. Automatic Check-In Reports
When the Base Station is programmed to send auto check-in reports, it
will dispatch the reports to the CMS accordingly.
After the Base Station is powered on, the first auto check-in report it sends
will be conditioned by the setting of the offset timer. Afterwards auto
check-in reports will be sent according to the setting of the auto check-in
timer.
The auto check-in timer will be reset whenever programmed mode is
entered.
<
<
N
N
O
O
T
T
E
E
>
>
If the setting of the offset timer or the auto check-in timer is changed, the
next auto check-in report will be sent according to the setting of the offset
timer. Afterwards auto check-in reports will be sent according to the
setting of the auto check-in timer.
6.2.1.8. Inactivity Timer
When the inactivity timer is enabled (the blue backlight of the yellow
button will be on), its countdown period starts immediately after the Base
Station is powered on or when the Base Station exits programming mode.
When the inactivity timer is not reset, the Base Station will send an
inactivity timer expired report to the CMS after warning time expires.
The inactivity timer can be reset by pressing the reset button once on the
Base Station, by inserting the Mobile Unit on the Base Station, or by an
action from any device with a button or from Passive Infrared Motion
Detector.
You can disable the inactivity timer by programming it as “off.” The blue
backlight will be off.
When the inactivity timer is enabled and toggled on by pressing the yellow
button, the blue backlight will be on. When the inactivity timer is enabled
and toggled off by pressing the yellow button, the blue backlight will be off.
When the yellow button is programmed as a non-emergency call button,
the inactivity timer can still be running. In this case you will have to disable
or enable the inactivity timer via programming, for you cannot toggle on/off
the inactivity timer by pressing the yellow button.
<
<
N
N
O
O
T
T
E
E
>
>
If no movement is detected during the preset inactivity time, the Base
Station will send CID event code 641 with a fixed zone number regardless
of the zones the triggered motion detectors occupy.