User's Manual
68
The interval between an AC power failure and the Base Station’s sending
the AC failure report (factory default is 5 minutes) is programmed as
explained in Step 10. System of 4.2. PC Programming Tool.
After AC power has been restored for more than 5 minutes, the Base
Station will send an AC power restored report to the CMS.
When the Base Station is experiencing an AC fault, it will not charge the
Mobile U nit. It will charge the Mobile Unit only after its AC power has been
restored.
6
.2.1.4. Base Station Low on Battery
When a low battery condition has lasted 4-6 minutes, the Base Station will
report to the CMS and the green LED blinks every 2 seconds. The report
will be sent to all reporting numbers except for the phone numbers
programmed for speech reporting.
After the battery voltage is restored and has lasted 5 minutes, the Base
Station will send a battery power restored report to the CMS and the green
LED will be steady on again.
6.2.1.5. Base Station’s Battery Disconnected
The Base Station detects battery absence in the following situations:
- Battery switched off
- Battery not connected
- Battery failure
When battery disconnection has lasted 30 minutes, the Base Station will
report to the CMS and the green LED blinks slowly.
After the battery is restored and the restoration has lasted 30 minutes, the
Base Station will send a battery restored report to the CMS and the green
LED will be steady on again.
6.2.1.6. Devices Low on Battery
When a device is low on battery, the Base Station’s green LED blinks
every 2 seconds (please refer to the figure on page 4 and the chart on
page 6).
After the faulty battery is replaced, the Base Station will instantly send a
battery restored report to the CMS regarding the particular device.
If multiple sensors are running low on battery, the green LED won’t stop
blinking until all the sensors’ low battery status has been cleared.