67
6.2.1.2. Non-Emergency Calls
Step 1.
Press the yellow button once or press the green reset button for 3
seconds when the Base Station is in idle mode. One short beep will
be emitted and the Base Station will dial the programmed
non-emergency call number.
<
<
N
N
O
O
T
T
E
E
>
>
The yellow button can be used as a non-emergency call button only after it
has been programmed as a non-emergency call button.
Step 2. If the call is successful, the Base Station will open two-way
communication between the call recipient and the Base Station. The
factory default of the communication time is 5 minutes. The
communication time is conditioned by the two-way timer function. The
orange backlight illuminates during the conversation.
<
<
N
N
O
O
T
T
E
E
>
>
Press a DTMF key for over 1 second during the two-way communication
to enable a designed shortcut function.
- Enter (1) to talk only.
- Enter (2) to open two-way voice communication.
- Enter (3) to listen in only.
- Press any DTMF key except for the designed hang-up key (9) to add
another preset communication period. Communication periods are
conditioned by the two-way timer function.
- When a DTMF key is pressed, its designed shortcut function will be
executed and the communication time extended simultaneously.
At 20 and 10 seconds before the communication time expires, 1 beep will
be emitted via the telephone handset to alert the user.
Step 3. Press DTMF (9) or the non-emergency call button to terminate the call.
The orange backlight dims and the Base Station returns to idle mode.
6.2.1.3. AC Power Checkup
If an AC power failure is detected to have lasted for 10 seconds or longer,
the green LED starts to blink as a visual warning to the user. 3G modules
will then be powered off, so SMS remote programming will become
unavailable. 3G modules will be powered on only during times of reporting.
An AC power failure report will be sent to all reporting numbers except for
the phone numbers programmed for speech reporting.
When AC power is restored, the green LED will be steady on again.
If an AC power failure has lasted for 5 minutes, the Base Station will send
an AC failure report to the CMS.
<
<