User's Manual
56
5. Device Management
You can use the local learning method to learn 100 devices into the Base
Station. These devices include:
Door Contact: DC
Water Sensor: WS
Panic Button: PB
Wrist Transmitter and Pendant Transmitter: WTR
Passive Infrared Motion Detector: IR
Smoke Detector: SD
Gas Detector: GAS
Carbon Monoxide Detector: CO
Heat Detector: HD
Glass Break Detector: GLS
Fall Sensor: FALL
5.1. Learning in Pendant #1, Pendant #2 and Other Devices
Step 1. When the Base Station is in idle mode, press and hold the yellow
button for 3 seconds to enter learning mode.
Step 2. The Base Station will emit 1 beep once the yellow button is pressed.
Release the yellow button when you hear 2 beeps, which indicate the
Base Station is now in learning mode. The blue backlight begins to
blink.
Step 3. Press the green reset button once. The Base Station will emit 1 beep.
Step 4. Press the button of Pendant #1 until the Base Station emits 2 beeps to
indicate Pendant #1 has been learned into Zone 1.
<
<
N
N
O
O
T
T
E
E
>
>
Only WTR and Fall Sensor can be learned into Zone 1 and Zone 2.
If the Base Station emits 3 beeps, that means a sensor has been
previously assigned to Zone 1.
Step 5. Press the red help button once. The Base Station will emit 1 beep.
Step 6. Press the button of Pendant #2 until the Base Station emits 2 beeps to
indicate Pendant #2 has been learned into Zone 2.
<
<
N
N
O
O
T
T
E
E
>
>
If the Base Station emits 3 beeps, that means a sensor has been
previously assigned to Zone 2.
The green reset button assigns a pendant to Zone 1 and the red help
button a pendant to Zone 2. If the green reset button or the red help button