User's Manual

53
Item Command Example & Usage Default
Inactivity timer
INACT INACT:PROG,1111,1,0,720,30
To configure settings of the inactivity timer (function type of
the yellow button, on or off, interval: 0~1440 minutes,
warning time: 0~60 minutes)
Button function type: 1 = away/home button, 2 =
non-emergency call button
On = 1, off = 0
1, 0, 720, 30
Callback time CBTI CBTI:PROG,1111,5,-1
To set callback time (duration: 0~1400 minutes, two-way
time: 1~60 minutes or -1 = no limits)
5, 5
Supervision SUPPR SUPPR:PROG,1111,720
To set the supervision timer (0~10080 minutes)
720
Speaker
volume levels
SPKVL SPKVL:PROG,1111,3,3,3
To set speaker volume levels (two-way: 1~5, talk only: 1~5,
others: 1~5)
2, 2, 3
Factory reset FTSET FTSET:PROG,1111,0,0
To execute a factory reset (to keep or not to keep NET
configurations, to keep or not to keep all devices and their
programmed attributes)
To keep NET configurations = 1; not to keep NET
configurations = 0
To keep all devices and their programmed attributes = 1; not
to keep all devices and their programmed attributes = 0
--
To set the CID
event code for
the red help
buttons
BTNEV BTNEV:PROG,1111,100
To set the CID event code sent when the Base Station’s red
help button or the Mobile Unit’s red help button is pressed.
100 = medical event
101 = personal emergency
120 = panic report
130 = burglary
100
To enable/disable
voice prompts
during guard time
and confirmation
beeps
SNDCR
SNDCR:PROG,1111,1,1
To enable/disable voice prompts during guard time and
confirmation beeps
1 = enable
0 = disable
1, 1
RF jamming
reports
JAMRP JAMRP:PROG,1111,1
To enable/disable RF jamming reports
1 = enable
0 = disable
1
AC power
failure reports
ACFRP ACFRP:PROG,1111,5
To disable AC power failure reports or to set the interval
between an AC power failure and the reporting of the power
failure
0 = disable
1-60 = 1~60 minutes
5