User's Manual
3
signal strength. DO NOT use a ZigBee Router without backup battery. A ZigBee router without battery will be powered
down during AC power failure and the sensor connected to the router will lose connection with ZigBee network. You
should plan your sensor installation location using only ZigBee router with backup battery.
Appendix
(The Appendix information is for developers only.)
Light Sensor Cluster ID
Device ID: Room Sensor 0x0302
Endpoint: 0x01
Server Side Client Side
Mandatory
Basic (0x0000) Basic (0x0000)
Identify(0x0003) Identify(0x0003)
Illuminance Measurement (0x0400)
Optional
Power Configuration(0x0001)
None
Temperature Measurement(0x0402)
Relative Humidity Measurement(0x0405)
Attribute of Basic Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x0000
ZCLVersion
Unsigned 8-bit
integer
0x00 –0xff
Read
only
0x01 M
0x0001 ApplicationVersion
Unsigned 8-bit
integer
0x00 –0xff
Read
only
0x00 O
0x0003
HWVersion
Unsigned 8-bit
integer
0x00 –0xff
Read
only
0 O
0x0004
ManufacturerName
Character
String
0 – 32 bytes
Read
only
Climax
Technology
O
0x0005
ModelIdentifier
Character
String
0 – 32 bytes
Read
only
(Model Version) O
0x0006
DateCode
Character
String
0 – 16 bytes
Read
only
O
0x0007
PowerSource
8-bit 0x00 –0xff
Read
only
M
0x0010
LocationDescription
Character
String
0 – 32 bytes
Read /
Write
O
0x0011
PhysicalEnvironment
8-bit 0x00 –0xff
Read /
Write
0x00 O
0x0012
DeviceEnabled
Boolean 0x00 –0x01
Read /
Write
0x01 M
Attribute of Identify Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x0000
IdentifyTime
Unsigned
16-bit integer
0x00 –0xffff
Read /
Write
0x0000 M
Attribute of Power Configuration Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x0035
BatteryAlarmMask
8-bit
bitmap
0000 000x
Read /
Write
0000 0000 O
Attribute of Illuminance Measurement Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional