Specifications
39
report.
Entry Delay 2 for Full Arm: Set Entry Delay Timer 2 for full arm mode. When a sensor
set to Start Entry Delay 2 is triggered under Full Arm mode, the control panel will begin
Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Exit Delay for Full Arm: Set the Exit Delay Timer when entering Full Arm mode. When
the user changes system mode to Full Arm, the panel will begin Exit Delay Timer
Countdown and enter Full Arm mode when the timer expires. The user must leave area
protected by sensors before the timer expires, otherwise an alarm will be activated with
the sensor is triggered.
Entry Delay 1 for Home Arm: Set Entry Delay Timer 1 for Home Arm mode. When a
sensor set to Start Entry Delay 1 is triggered under Home Arm mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Entry Delay 2 for Home Arm: Set Entry Delay Timer 2 for Home Arm mode. When a
sensor set to Start Entry Delay 2 is triggered under Home Arm mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Alarm Length: Set the duration the external siren should sound when an alarm is
activated.
Cross Zone Timer: Please refer to 10.3 Cross Zone Timer for details
Fire Verification Time: Please refer to 10.4 Fire Verification Timer below for details.
Sound Setting
Door Chime Setting: this function is available only when the attribute of Door Contact
(DC) and/or PIR detector (IR) is set as Door Chime.
The Control Panel sounds a Door Chime (Ding-Dong Sound) while the DC and/or IR is
activated in Disarm / Full / Home / Entry mode.
Entry Delay Sound for Full Arm: this is for you to decide whether the Control Panel
sounds count-down beeps and volume of beep during the entry delay time in the full
arm mode.
Exit Delay Sound for Full Arm: this is for you to decide whether the Control Panel
sounds count-down beeps and volume of beep during the exit delay timer in the full arm
mode.
Entry Delay Sound for Home Arm: this is for you to decide whether the Control Panel
sounds count-down beeps and volume of beep during the entry delay time in the home
arm mode.
Exit Delay Sound for Home Arm: this is for you to decide whether the Control Panel
sounds count-down beeps and volume of beep during the exit delay timer in the home
arm mode.