User's Manual
41
10. Appendix 
Appendix A: Sensor Groups 
Senso
r 
Group 
Physical 
Type 
Short Description Description  Other 
Allowed 
Groups 
0  Keypad/Pull 
Station 
Fixed Panic 
24-hour audible fixed emergency buttons, 
instant alarm, always armed 
2, 4 
1  Keyfob/Panic 
Button 
Portable Panic 
24-hour audible portable emergency buttons, 
instant alarm, always armed 
3, 6 
2  Keypad/Pull 
Station 
Silent Fixed Panic 
24-hour silent fixed emergency buttons, 
instant alarm, no siren, always armed 
0, 4 
3  Keyfob/Panic 
Button 
Silent Portable Panic
24-hour silent portable emergency buttons, 
instant alarm, no siren, always armed 
1, 6 
4  Keypad  Fixed Auxiliary 
24-hour auxiliary sensor, instant alarm, 
always armed 
0, 2 
6  Keyfob/Panic 
Button 
Portable Auxiliary 
24-hour portable auxiliary alert button, instant 
alarm, always armed 
1, 3 
8  Contact  Cabinet/Safe 
Special belongings, such as gun cabinets 
and wall safes, instant alarm, always armed 
8, 10, 11, 
13, 14, 16, 
19, 31, 36
10  Contact  Door/Window 
Entry and exit doors, standard delay alarm, 
armed in Stay and Away modes 
8, 11, 13, 
14, 16, 19, 
31, 36 
11  Contact  Extended 
Delay/Door 
Garage doors and entrances, extended delay 
alarm, armed in Stay and Away modes 
8, 10, 13, 
14, 16, 19, 
31, 36 
13  Contact  Door/Window or 
Glassbreak 
Exterior doors and windows, instant alarm, 
armed in Stay and Away modes 
8, 10, 11, 
14, 16, 19, 
31, 36 
14  Contact  Door/Window 
Interior doors, instant alarm, armed in Stay 
and Away modes 
8, 10, 11, 
13, 16, 19, 
31, 36 
15  Motion  Motion 
Motion Sensors, follower,    armed in Stay 
and Away modes 
17, 18, 20, 
25, 50 
16  Contact  Door/Window 
Interior Doors, instant alarm, armed in Away 
mode Only 
8, 10, 11, 
13, 14, 19, 
31, 36 