10.  Appendix   
10.1. Fault Event Description 
During operation, when the panel detects faulty events, the panel will log the event and make 
reports. When fault events exist in the system, the panel Fault LED will light up and the panel will 
emit a beep every 30 seconds. 
  Fault Event Table 
Fault Event  Descriptions 
Panel AC Failure 
The Control Panel’s AC power is disconnected 
When AC failure is detected, the panel will turn off both Ethernet and mobile 
network functions when idle to conserve power. Ethernet and mobile network 
will be activated temporarily when an event is detected by the panel (i.e. alarm 
trigger) to send report, and will turn off again after finishing report. 
Accessing the panel via remote server XMPP connection is disabled during AC 
failure. 
Panel Low Battery 
The panel’
s backup battery is only used when AC failure is detected. When the 
backup battery voltage is low, the panel low battery event is generated 
Panel Tamper 
The tamper switch on back of the panel is not compressed against the back 
cover. This means the panel’s cover is opened and not properly sealed. 
Battery Dead/Missing 
The panel cannot detect backup battery, this means the battery is either 
dysfunctional, or the battery switch is not slid to ON position. 
Interference/Jamming 
The panel detects radio frequency jamming, which will affect its ability to 
receive signal from RF devices (Does not include ZigBee/Z-wave/Wi-fi signal) 
Device Low Battery 
The accessory device at indicated zone number is low on battery 
Device AC Failure 
The accessory device at indicated zone number does not have AC power 
connection. 
Device Tamper 
The tamper switch of the device at indicated zone number is open 
Device Supervision 
Failure 
The panel was unable to receive supervision signal sent from accessory device 
at indicated zone number for the duration of Supervision Timer programmed. 
(i.e. If Supervision Timer is 
set to 12 hours, the panel will generate supervision 
failure event after failing to receive supervision signal for 12 hours) 