User's Manual
Table Of Contents
- Table of Contents
 - 1. Introduction
 - 2. Panel Information
 - 3. Getting Started
 - 4. Connection to Panel Webpage
 - 5. Device Management
 - 6. Program the System
 - 7. Network Settings
 - 8. System Settings
 - 9. Event & History
 - 10. Appendix
 - Federal Communication Commission Interference Statement
 
  Area 
Each Area has different Duress Code, Master Code, and Temporary Code. Select the Area 
to program the code setting in this area. 
  Duress Code 
The Duress Code is designed for transmitting a secret & silence alarm. 
When Duress Code is used for accessing the system, the Control Panel will report a 
secret alarm message without sounding the siren to the Central Monitoring Station to 
indicate of a Duress Situation in Progress. 
The Duress Code consists of 4-6 digits and is not activated as default by the factory. 
  Guard Code 
The Guard Code is designed for security patrol personnel to arm/disarm the system. It can 
be set the same as a User PIN Code. 
The Guard Code consists of 4-6 digits and is not activated as default by the factory. 
  Master Code 
This function is currently disabled. 
  Temporary Code 
Temporary Code is also used to arm/disarm the system, but it is for a temporary user. The 
temporary Code is ONLY valid for one-access per arming and disarming. Afterwards, the 
Temporary Code will be automatically erased and needs to be reset for a new Temporary 
user. 
The Temporary Code consists of 4-6 digits and is not activated as default by the factory.   
  Latch Option 
This is to program the Latch Key Reporting feature for Temporary Code. Please click the 
box to select the options. 
  Latch  Latch Report ON = Whenever the system is armed, home/ day home/ night 
home armed or disarmed, the Panel will transmitt Contact ID code / SMS message / 
GPRS reporting (according to pre-setting) to notify the Central Monitoring Station. 
  Latch  Latch Reprot OFF = Whenever the system is armed, home/ day home/ night 
home armed or disarmed, the Panel will NOT transmit reporting(s) to notify the Central 
Monitoring Station. 
  Delete 
Except Master Code which can’t be disabled in any way, Temporary and Duress Code can 
be disabled by cleaning the code box and leaving the box as blank.         
62 