  Jamming Report: this function is reserved. 
  Auto Check-in: this is to select whether the Control Panel needs to send check-in 
reporting to the Central Station automatically and to select the period of time between 
check-in reports. Options available are Disable, 1 hour, 2 hours, 3 hours… up to 4 
Weeks.   
  Auto Check-in Offset Period:  This is to set the time delay before the first Auto 
Check-In report is made. After power is supplied or re-supplied to the Control Panel, a 
test report will be sent to the Central Monitoring Station (CMS) based on the Offset 
Period. This is used to test whether the CMS is able to receive the report from the 
Panel accurately.   
After this test report is sent, the Control Panel will then send reports at regular interval 
based on the setting of the Auto Check-in Report.      
For example, if Offset Period is set to 2 Hours, and Auto Check-in Report is set to 12 
hours, the Control Panel will transmit an event code 602 to the CMS after 2 hours, and 
then report 602 event code periodically at a regular intervals of 12 hours.   
  IR Camera Resolution of Alarm Images: This is to select the resolution and number 
of pictures taken by PIR Camera when the camera detects a movement in armed 
mode. 
Options available are 320x240x3 images (Default),  320x240x6 images and 
640x320x3 images.   
  Outdoor IR Camera in Greysclae: This is to select whether pictures from Outdoor PIR 
Camera should be taken in greyscale instead of color pictures.   
Options available are: Disable (Color Picture) and Enable (Greyscale picture) 
  Bypass Ethernet: Select to enable or disable Bypass Ethernet function. When YES is 
selected, the Control Panel will bypass connection fault when Ethernet cable 
unplugged status is detected. 
Area Setting 
  Area: Select operation area to apply setting.   
  Final Door:  If set to On:  When the system is Away Armed and under exit timer 
countdown, if a opened Door Contact set to Entry attribute is closed, the system will 
automatically arm the system even if the exit delay timer has not expired yet. 
  Arm Fault Type: Select how the system should respond when it is being armed under 
fault condition. 
  Confirm: The panel will first display a “Mode Change Fault” message and emit 2 
beeps. Arming again within 10 seconds will force arm the system. 
  Direct  Arm: The system will be force armed directly without displaying fault 
message and report an event. 
  Tamper Alarm: Select  whether the siren should sound  alarm when the tamper  is 
triggered. 
  Full Arm: when tamper is triggered under Full arm mode, Control Panel raises a 
local alarm and sends report to the monitoring center. While under Home Arm or 
Disarm modes no alarm will be activated, nor report sent. 
  Always: Control Panel raises a local alarm and send report for tamper-trigger in all 
modes.   
  Supervision Check: Select to enable or disable system supervision function. When 
ON is selected, the Control Panel will monitor the accessory devices according to the 
supervision signal received.   