User's Manual

81
10.6. Event Code
100 Medical
When a device set to Medical attribute is triggered.
101 Personal emergency
When a device set to Personal Emergency attribute is triggered.
110 Fire
When a device set to Fire attribute is triggered.
111 Smoke
When the Smoke Detector (SD) set to Smoke Alarm is triggered.
When the Smoke Detector (SD) set to Fire Verification verifies an alarm during Fire
Verification Time.
118 Near Alarm
When the Smoke Detector (SD) set to Fire Verification is triggered.
120 Panic
When a device set to Panic attribute is pressed.
121 Duress
When the Duress Code is entered to disarm or arm the system.
122 Silent Panic
When a device set to Silent Panic is pressed.
130 Burglar
Whenever a device set as Burglar Instant is triggered.
Whenever a device set as Burglar Instant is triggered under Disarm, Full Arm or
Home Arm mode.
131 Burglar Perimeter
When a device set as Entry is triggered in Full Arm mode.
When a device set as Burglar Follow is triggered during Full Arm Entry Time and the
system is not disarmed before entry time expiry.
132 Burglar Interior
When a device set at Entry is triggered in Home Arm mode.
When a device set as Burglar Follow is triggered during Home Arm Entry Time and
the system is not disarmed before entry time expiry.
136 Burglar Outdoor
Whenever a device set at Burglar Outdoor is triggered.
137 Panel Tamper/ Panel Tamper Restore
When the panels tamper protection is triggered.
When the panels tamper function is restored.
139 Burglar Verified.
When a sensor set to Cross Zone attribute verifies an alarm.
147 Sensor Supervision Failure/ Sensor Supervision Restore
When the panel fails to receive supervision signal from a device within preset