5. Device Management
The Device Management section allows you to learn in, edit, control and view all available
accessory devices that can be included in the HSGW Series Control Panel.
5.1. Learning
Use this function to add new devices into the Control Panel. HSGW Series supports up to 160
zones of accessory devices, in 2 areas, up to 80 zones each area.
The following types of accessory devices are supported:
RF device: All Climax RF devices are supported.
IP Cameras: The Control Panel is compatible with Climax VST-1818 Series IP Camera. Up
to 6 IP Cameras are supported.
Z-Wave Device: Available for Z-Wave modules only, other modules requires additional
USB Z-Wave Dongle.
5.1.1. Add Sensor
Step 1. Click on “Learning” to enter learn page.
Step 2. Click on “Start” to enter learning mode.
Step 3. Press the test or learn button on the each device or any button on the Remote
Controller. (Please refer to each sensor’s user manual for test or learn button position).
<NOTE>
For IP Camera VST-1818 Series, press and hold the Privacy button for 10 seconds.
Step 4. When the system received the signal transmitted from device, the screen will display its
information for selection.
<NOTE>
It takes 5-10 seconds for the Control Panel to receive a learn code from Z-Wave
Sensor.
Step 5. Click “Add” to include selected device into panel. If the sensor you wish to learn into
already exists in the system, the sensor information will be displayed in the Learned