User's Manual
14
During two-way communication, you
can use DTMF command to switch the
communicating method. Please refer to
section 4.2. Alarm Activation.
The first digit of Access Code must be
entered within 15 sec. Otherwise,
CTC-1041RV will disconnect the call
automatically.
To terminate the call, press DTMF (9)
or RESET BUTTON on CTC-1041RV.
If the 5-minute waiting period is up,
CTC-1041RV will automatically exit
this waiting mode and return to idle
mode.
Command #41 (Auto Answer for
Remote Programming) will not be able
to proceed during the 5-mins Call-
back time.
Command 39
Dialing Mode
This function is for you to select the dialing
method of your telecommunications.
There are two dialing methods available for
user:
Function Selection
Result
0 TONE
1 PULSE
Factory Default is set as (0), Tone.
Command 40
Set Access Code
The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
It consists of 4 digits and has been set to
(1111) as factory default. Before you set
your own Access Code, (1111) must be
keyed in.
To set a new Access code; enter the
desired (4-digit number) in Function
Selection.
Command 41
Auto Answer for Remote Programming
CTC-1041RV can be programmed to auto
answer incoming phone calls after a pre-
set number of rings have been reached.
The number of rings range from (00) (no
auto answer) to (32) rings.
Function Selection
Result
(00) OFF
(01) - (32) ON
Factory Default is (20) Rings.
<
<
N
N
O
O
T
T
E
E
>
>
If 00 is selected, it means CTC-
1041RV cannot auto-answer the call
by ring count. If you want to do
Remote programming, please follow
the Remote Programming method
described in System Conifuration, I.
Entering Programming Mode: 2.
Remote Programming Mode.
Command 43
Periodic Test Call
CTC-1041RV can be programmed to make
test calls periodically from (00) (no test call)
to every (1) - (7) or 30 days:
Function Selection
Result
(0) OFF
(1) - (7) 1 - 7 DAYS
(8) 30 DAYS
Factory Default is set as (0), OFF.
<
<
N
N
O
O
T
T
E
E
>
>
Whenever programming mode is
accessed, CTC-1041RV will reset the
Periodic Test Call timer.
Periodic Test Call will only function
with telephone numbers assigned to
Digital reporting method in Command
20-24.