User's Manual

13
Command 38
Follow-On & Call-Back Function
The Command is available for Digital
Reporting Methods (when Command #20 -
#24 is set as (0), (1) or (2).
Function Selection
Result
(0) Follow-On
(1) Call-Back
(2) Follow-On & Call-Back
Factory Default is as (0), Follow-On.
When this function is programmed as (0),
after a successful alarm reporting
(triggered by pressing the Help button on
the Medical Panel) to the Monitoring
Center, CTC-1041RV will automatically
enter the Follow-On mode as specified by
Command (45). If the alarm is triggered by
a Talking Pendant (WTRVS), the system
will automatically enter Wait for
Command” mode (see Command 45) and
wait for the DTMF 2 signal pressed by the
Monitoring Center to set up two-way
communication between WTRVS, the
Monitoring Center and all CTC-808RVs
learned into the system. If the alarm is
triggered by CTC-808RV, the system will
automatically enter “Wait for Command”
mode (see Command 45) and wait for the
DTMF 2 signal pressed by the Monitoring
Center to set up two-way communication
between the Monitoring Center and all
CTC-808RVs learned into the system.
When this function is programmed as (1),
after a successful alam reporting (triggered
by pressing the Help button on the Medical
Panel) to the Monitoring Center, CTC-
1041RV will automatically hang up the line
and start a 5-minute waiting period to auto
answer any incoming phone calls from the
Monitoring Center. The Monitoring Center
personnel should enter an authorized
access code (default: 1111), followed by (#)
to set up the two way communication
between CTC-1041RV and the Monitoring
Center.
If the alarm is triggered by a Talking
Pendant (WTRVS), the system will wait for
an authorized access code (default 1111)
followed by (#) during the 5-minute waiting
period to open two-way communciation
between WTRVS, the Monitoring Center
and all CTC-808RVs learned into the
system.
If the alarm is triggered by CTC-808RV,
the system will wait for an authorized
access code (default 1111) followed by (#)
during the 5-minute waiting period to open
two-way communciation between the
Monitoring Center and all CTC-808RVs
learned into the system.
When this function is programmed as (2),
after a successful alarm reporting
(triggered by pressing the Help button on
the Medical Panel) to the Monitoring
Center, CTC-1041RV will automatically
enter the Follow-On mode as specified by
Command (45). If the alarm is triggered by
a Talking Pendant (WTRVS), the system
will automatically enter Wait for
Command” mode (see Command 45) and
wait for the DTMF 2 signal pressed by the
Monitoring Center to set up two-way
communication between WTRVS, the
Monitoring Center and all CTC-808RVs
learned into the system. If the alarm is
triggered by CTC-808RV, the system will
automatically enter “Wait for Command”
mode (see Command 45) and wait for the
DTMF 2 signal pressed by the Monitoring
Center to set up two-way communication
between the Monitoring Center and all
CTC-808RVs learned into the system.
Once Follow-On Mode is terminated, CTC-
1041RV will automatically start a 5-minute
waiting period to auto answer any incoming
phone calls from the Monitoring Center. The
Monitoring Center personnel should enter
an authorized access code (default: 1111),
followed by (#) to set up the two way
communication between CTC-1041RV and
the Monitoring Center. If the alarm is
triggered by a Talking Pendant (WTRVS),
the system will wait for an authorized
access code (default 1111) followed by (#)
during the 5-minute waiting period to open
two-way communciation between WTRVS,
the Monitoring Center and all CTC-808RVs
learned into the system. If the alarm is
triggered by CTC-808RV, the system will
wait for an authorized access code (default
1111) followed by (#) during the 5-minute
waiting period to open two-way
communciation between the Monitoring
Center and all CTC-808RVs learned into
the system.
<
<
N
N
O
O
T
T
E
E
>
>