Instruction manual
HUMIDIFY AND HUMIDITY SETPOINT
21INSTRUCTION MANUAL
>> HUMIDIFY SETPOINT: Allows you to increase and maintain the relative humidity
at a specific setpoint. Once you choose HUMIDIFY follow these easy steps:
:: The HUM setpoint with - and + icons allow you to lower and raise your setpoint.
* Example of the typical use of the Humidify Function: If the current humidity is 30% your
Climatouch
™
thermostat will initiate the humidifier to function until Setpoint 50% is
reached. In order to humidify you must set the humidity setpoint above the current
humidity.
AUTOMATIC HUMIDITY CONTROL
20 Climatouch
™
CT0-7TC-32ADH
>> In order to reduce condensation, humidity must be controlled and air movement
must be generated. As the exterior temperature drops, the humidity level
needs to decrease if condensation is to be controlled.
HUMIDITY AUTO: Climatouch automatically adjusts the humid-
ity set point based on the current indoor temperature and
humidity as well as the current outdoor temperature in order
to maintain a maximum comfort level and eliminate conden-
sation. The automatic humidity setpoint is determined accord-
ing to the following standard humidity table.
1
Setpoint Outdoor Temp in °C Outdoor Temp in °F
15% -29 -20
20% -24 -10
25% -18 0
30% -12 10
35% -7 20
40% -7 -20
HUMIDITY MANUAL: The user selects the humidity setpoint.
1
Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT (90064)