TS - Vertical Downow – Dimensional Data
Notes:
1. While clear access to all removable panels is not required, installer
should take care to comply with all building codes and allow adequate
clearance for future eld service.
2. Front & Side access is preferred for service access. However, all
components may be serviced from the front access panel if side
access is not available.
3.
Condensate is 3/4” FPT PVC and is switchable from front to side.
Legend:
CAP = Control Access Panel
BSP = Blower Service Panel
CSP = Compressor Access Panel
ASP = Alternative Service Panel
Vertical
Downow
Model
Overall Cabinet
*A
Width
B
Depth
C
Height
018
in
cm
22.4
56.8
25.6
65.1
48.4
122.9
024 -
030
in
cm
22.4
56.8
25.6
65.1
52.5
133.4
036
in
cm
25.4
64.5
30.6
77.8
54.5
138.4
042 -
048
in
cm
25.4
64.5
30.6
77.8
58.5
148.6
060 -
070
in
cm
25.4
64.5
30.6
77.8
62.5
158.8
Vertical
Downow
Model
Water Connections
1 2 3 4 5
Loop
In
D
Loop
Out
E
HWG
In
F
HWG
Out
G
H
Water
Loop
FPT
HWG
FPT
018
in
cm
17.2
43.7
9.3
23.6
5.4
13.7
2.4
6.1
3.6
9.2
3/4” 1/2”
024 -
030
in
cm
17.9
45.5
10.5
26.7
5.7
14.5
2.4
6.1
3.6
9.2
3/4” 1/2”
036
in
cm
17.9
45.5
10.5
26.7
5.7
14.5
2.4
6.1
3.6
9.2
3/4” 1/2”
042 -
048
in
cm
17.9
45.5
10.5
26.7
5.7
14.5
2.4
6.1
3.6
9.2
1” 1/2”
060 -
070
in
cm
17.9
45.5
10.5
26.7
5.7
14.5
2.4
6.1
3.6
9.2
1” 1/2”
Vertical
Downow
Model
Electrical Knockouts
J
1/2”
K
1/2”
L
3/4”
Low
Voltage
External
Pump
Power
Supply
018
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
024 -
030
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
036
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
042 -
048
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
060 -
070
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
*Does not include air lter supports. Add 2” (5.1cm) when a 1” (25.4mm) lter is used, add 3”
(7.6cm) when a 2” (50.8mm) lter is used.