Right Return Straight Discharge
Front
N
P
Blower
Outlet
M
O
Right Return
Front
Straight
Discharge
5
CSP
Back
Discharge
Condensate
3 / 4” IPT
H
Front-View
4
3
2
1
A
CAP
BSP
Right Return Right View -
Air Coil Opening
Air Coil
C
V
U
B
ASP
T
S
Front
P
Blower
Outlet
M
O
Left Return Straight Discharge
Front
BSP
LEFT RETURN RIGHT RETURN
Air Coil
CSP
Front
Left Return Left View -
Air Coil Opening
1.1 [27.9mm]
C
V
T
SU
B
Unit Hanger Detail
X
Y
Front
Z
Right Return Back Discharge
A
Air Coil Side
C
R
P
Blower
Outlet
Q
O
ASP
CSP
BSP
2’ [61cm] Service
Access
Front
Left Return
H
CSP
Condensate
3 / 4” IPT
ASP
2’ [61cm] Service
Access
Air Coil Side
O
A
C
Left Return Back Discharge
P
Blower
Outlet
Q
R
BSP
N
2’ [61cm] optional
service access
2’ [61cm] optional
service access
G
F
D
E
3.25
[82.6mm] 3.25
[82.6mm]
1.6 [40.6mm]
Model
X Y Z
in. cm. in. cm. in. cm.
018-030 62.1 157.7 24.5 62.2 20.3 51.5
036 71.1 180.6 27.5 69.9 23.3 59.1
042-048 76.1 193.3 27.5 69.9 23.3 59.1
060-070 81.1 206.0 27.5 69.9 23.3 59.1
K
L
J
1.6 [40.6mm]
006-012 43.1 109.5 24.5 62.2 20.3 51.5
Power Supply
3 / 4” [19.1mm] Knockout
1 / 2” [12.7mm]
Knockout
Low Voltage
1 / 2” [12.7mm]
Knockout
5
Straight
Discharge
Back
Discharge
Note: Choose either
back or straight discharge
Note: Choose either
back or straight discharge
Filter Rails Removed
See A ---- for accessory air lter frame with duct collar
TS - Horizontal – Dimensional Data
Horizontal
Model
Discharge Connection
Duct Flange Installed
Return Connection
Using Return Air Opening
Return Connection
Using Optional Air Filter Frame
M N
O
Supply
Height
P
Supply
Width
Q R
S
Return
Width
T
Return
Height
U V
S
Return
Width
T
Return
Height
U V
006 - 012
in
cm
5.3
13.4
4.1
10.3
9.0
22.5
9.0
22.5
5.3
13.4
4.1
10.3
17.1
43.4
15.3
38.9
2.1
5.3
1.0
2.5
17.7
45.0
14.2
36.1
2.3
5.8
1.7
4.3
018
in
cm
3.6
9.3
2.0
5.1
15.5
39.4
12.5
31.8
3.6
9.2
2.0
5.2
28.1
71.4
17.3
43.9
6.2
15.7
1.0
2.5
33.8
85.8
16.2
41.0
2.3
5.8
1.7
4.3
024 - 030
in
cm
3.6
9.3
2.0
5.1
15.5
39.4
12.5
31.8
3.6
9.2
2.0
5.2
32.1
81.5
17.3
43.9
2.3
5.8
1.0
2.5
33.8
85.8
16.2
41.0
2.3
5.8
1.7
4.3
036
in
cm
*3.1
7.9
1.2
3.1
19.0
48.3
17.5
44.5
*3.1
7.9
1.0
2.6
36.1
91.7
19.3
49.0
2.3
5.7
1.0
2.5
34.8
88.3
18.2
46.1
3.1
7.8
1.7
4.3
042 - 048
in
cm
3.1
7.9
1.2
3.1
19.0
48.3
17.5
44.5
3.1
7.9
1.0
2.6
41.1
104.4
19.3
49.0
2.3
5.7
1.0
2.5
39.8
101.0
18.2
46.1
3.1
7.8
1.7
4.3
060 - 070
in
cm
3.1
7.9
1.2
3.1
19.0
48.3
17.5
44.5
3.1
7.9
1.0
2.6
46.1
117.1
19.3
49.0
2.3
57
1.0
2.5
44.8
113.7
18.2
46.1
3.1
7.8
1.7
4.3