TS - Horizontal – Dimensional Data
Notes:
1. While clear access to all removable panels is not required, installer
should take care to comply with all building codes and allow adequate
clearance for future eld service.
2. Horizontal units shipped with lter bracket only. This bracket should
be removed for return duct connection
3. Discharge ange and hanger brackets are factory installed.
4. Condensate is 3/4” FPT.
5. Blower service panel requires 2’ service access.
6. Blower service access is through back panel on straight discharge
units or through panel opposite air coil on back discharge units.
Legend:
CAP = Control Access Panel
BSP = Blower Service Panel
CSP = Compressor Access Panel
ASP = Alternative Service Panel
Horizontal
Model
Overall Cabinet
*A
Width
B
Length
C
Height
006 -
012
in
cm
22.4
56.8
43.1
107.8
17.3
43.1
018
in
cm
22.4
56.8
62.2
158.0
19.3
48.9
024 -
030
in
cm
22.4
56.8
62.2
158.0
19.3
48.9
036
in
cm
25.4
64.5
71.2
180.8
21.3
54.0
042 -
048
in
cm
25.4
64.5
76.2
193.5
21.3
54.0
060 -
070
in
cm
25.4
64.5
81.2
206.2
21.3
54.0
Horizontal
Model
Water Connections
1 2 3 4 5
Loop
In
D
Loop
Out
E
HWG
In
F
HWG
Out
G
H
Water
Loop
FPT
HWG
FPT
006 -
012
in
cm
3.7
9.3
9.7
24.2
N/A N/A
0.8
2.0
1/2” N/A
018
in
cm
2.1
5.2
10.0
25.4
13.9
35.2
16.9
42.9
0.6
1.5
3/4” 1/2”
024 -
030
in
cm
2.1
5.2
10.0
25.4
13.9
35.2
16.9
42.9
0.6
1.5
3/4” 1/2”
036
in
cm
3.4
8.6
10.8
27.5
15.6
39.7
18.9
47.9
0.6
1.5
3/4” 1/2”
042 -
048
in
cm
3.4
8.6
10.8
27.5
15.6
39.7
18.9
47.9
0.6
1.5
1” 1/2”
060 -
070
in
cm
3.4
8.6
10.8
27.5
15.6
39.7
18.9
47.9
0.6
1.5
1” 1/2”
Horizontal
Model
Electrical Knockouts
J
1/2”
K
1/2”
L
3/4”
Low
Voltage
External
Pump
Power
Supply
006 -
012
in
cm
3.8
9.4
6.3
15.6
8.8
21.9
018
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
024 -
030
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
036
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
042 -
048
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
060 -
070
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
Water Connections -
Units with ClimaDry
®
1 2
Loop
In D
Loop
Out E
N/A N/A
2.1
5.2
10.0
25.4
5.96
15.14
13.13
33.35
5.96
15.14
13.13
33.35
5.96
15.14
13.13
33.35
5.96
15.14
13.13
33.35
*Does not include air lter supports. Add 2” (5.1cm) when a 1” (25.4mm) lter is used, add 3”
(7.6cm) when a 2” (50.8mm) lter is used.