Specifications
ClimateMaster works continually to improve its products. As a result, the design and specications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specic information on the current design and specications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
Revised: 17 July, 2013
LC377 - 36
TS Series 60Hz - HFC-410A Submittal Data Eng/I-P
Page ______ of ______
Dehumidication Mode Settings: The dehumidication mode setting provides eld selection of humidity control. When
operating in the normal mode, the cooling airow settings are determined by the cooling tap setting above. When
dehumidication is enabled there is a reduction in airow in cooling to increase the moisture removal of the heat pump. Consult
submittal data or specications catalog for the specic unit series and model to correlate speed tap to airow in CFM. The
dehumidication mode can be enabled in two ways.
1. Constant Dehumidication Mode: When the dehumidication mode is selected (via DIP switch or jumper setting), the
ECM motor will operate with a multiplier applied to the cooling CFM settings (approx. 20-25% lower airow). Any time
the unit is running in the cooling mode, it will operate at the lower airow to improve latent capacity. The “DEHUM” LED
will be illuminated at all times. Heating airow is not affected. NOTE: Do not select dehumidication mode if cooling
setting is tap 1.
2. Automatic (Humidistat-controlled) Dehumidication Mode: When the dehumidication mode is selected (via DIP switch
or jumper setting) AND a humidistat is connected to terminal DH (version II) or HUM (version I), the cooling airow will
only be reduced when the humidistat senses that additional dehumidication is required. The DH (or HUM) terminal is
reverse logic. Therefore, a humidistat (not dehumidistat) is required. The “DEHUM” LED will be illuminated only when the
humidistat is calling for dehumidication mode. Heating airow is not affected. NOTE: Do not select dehumidication
mode if cooling setting is tap 1.
Y
GGGG R
W
O
Y2
Y1
G
R
C
Y2
Y1
G
O
W
C
R
DH
AL1
A
A
AL1
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
SW9
OFF
ON
G
DEHUM
CFM
TB1
J1
S1
Thermostat
Input LEDs
CFM Counter
1 flash per 100 CFM
ECM Motor
Low Voltage
Connector
1/4" Spade
Connections
to CXM or
DXM Board
Thermostat
Connections
Dehumidification
LED
Fan Speed Selection DIP Switch
ECM Interface Board version II
(P/N 17B0019N01)
ECM Control