3
climatemaster.com
Tranquility
®
22 Digital (TZ) Series IOM - 60Hz HFC-410A
Rev.: 17 Jan., 2013B
Model Nomenclature: General Overview
WARNING!
WARNING!
CAUTION!
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal pro ciency requirements.
CAUTION! To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
lters will quickly become clogged with construction dirt
and debris, which may cause system damage.
WARNING! All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service, or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Noti cation of installation, operation or maintenance
information, which is important, but which is not hazard-
related.
A = Current Revision for 030, 042, 048
B = Current Revision for 024, 036, 060
B0 2 4 DG 0 2 C L T
4 5 6 7
8
91011121314
024, 030, 036, 042, 048, 060
UNIT SIZE
RETURN AIR FLOW CONFIGURATION
VOLTAGE
CONTROLS
D = DXM2
REVISION LEVEL
HEAT EXCHANGER OPTIONS
CABINET
SUPPLY AIR FLOW &
MOTOR CONFIGURATION
TZ
1 2
TZ = Tranquility
®
22 Digital
SERIES
V
3
V = Vertical Up
CONFIGURATION
Copper
Cupro-Nickel
No HWG
AJ
HWG W/Pump (Standard)
CN
2 = Magna Internal Flow Controller - Closed Loop
WATER CIRCUIT OPTIONS
S
15
S = Standard
STANDARD
H = Horizontal
0 = Residential
Supply
Configuration
Motor
T TZV
BTZH
STZH
Top
Back
Straight
ECM
ECM
ECM
5 = Motorized Modulating Valve (Central Pumping Applications) - Closed Loop
Tin Plated Air Coil
L = Left Return w/ 1” Merv 8 pleated filter and frame
R = Right Return w/ 1” Merv 8 pleated filter and frame
6 = Motorized Valve (Modulating) Open Loop Applications, High System Pressure Drop
G = 208-230/60/1
In Position 11 and 12, only the following combinations are available:
Without HWGWith HWG Description
2A2C Internal Flow Controller with Copper Water Coil
5A5C Motorized Modulating Valve with Copper Water Coil
6J6N Motorized Modulating Valve with Cupro-Nickel Water Coil
WARNING!
NOTE: Above model nomenclature is a general reference. Consult individual speci cation sections for detailed information.
WARNING! The EarthPure
®
Application and Service
Manual should be read and understood before attempting
to service refrigerant circuits with HFC-410A.