Specifications
TY Series 60Hz - HFC-410A Submittal Data Eng/I-P
ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specifi c information on the current design and specifi cations. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
Page ______ of ______Revised: 30 January, 2015LC992 - 32
TY - Vertical Upfl ow Dimensional Data
Vertical
Model
Electrical Knockouts
J
1/2”
K
1/2”
L
3/4”
Low
Voltage
Low
Voltage
Power
Supply
024 - 060
in
cm
4.1
10.5
7.1
18.1
10.1
25.7
Notes:
1. While clear access to all removable panels is not
required, installer should take care to comply with all
building codes and allow adequate clearance for future
fi eld service.
2. Front & Side access is preferred for service access.
However, all components may be serviced from the front
access panel if side access is not available.
3. Discharge fl ange is fi eld installed.
4. Condensate is 3/4” FPT.
5. Units shipped with fi lter rails. These rails should be
removed for return duct connection. See Aff---- for
accessory air fi lter frame with duct collar.
Legend:
CAP = Control Access Panel
BSP = Blower Service Panel
CSP = Compressor Access Panel
ASP = Alternative Service Panel
Vertical
Upfl ow
Model
Overall Cabinet
A
Width
B
Depth
C
Height
024 - 030
in
cm
21.5
54.6
21.5
54.6
40.0
101.6
036 - 042
in
cm
21.5
54.6
26.0
66.0
45.0
114.3
048 - 060
in
cm
24.0
61.0
32.5
82.6
46.0
116.8
Vertical
Upfl ow
Model
Water Connections - Standard Units
123
Loop
In
D
Loop
In
E
Loop
Out
F
Loop
Out
G
Cond. 3/4”
FPT
Loop
In/Out
FPT
HI
024
in
cm
1.9
4.8
1.4
3.6
13.8
35.1
1.4
3.6
8.1
20.6
1.4
3.6
3/4”
030
in
cm
1.9
4.8
1.4
3.6
15.2
38.6
1.4
3.6
8.1
20.6
1.4
3.6
3/4”
036
in
cm
1.9
4.8
1.4
3.6
15.7
39.9
1.4
3.6
8.1
20.6
1.4
3.6
3/4”
042
in
cm
1.9
4.8
1.4
3.6
16.6
42.0
1.4
3.6
8.1
20.6
1.4
3.6
3/4”
048
in
cm
1.9
4.8
1.4
3.6
16.6
42.2
1.4
3.6
8.1
20.6
1.4
3.6
1”
060
in
cm
1.9
4.8
1.4
3.6
17.2
43.7
1.4
3.6
8.1
20.6
1.4
3.6
1”
Air Coil Side
Front
‡
†
1”
1”
1”
6”
Recommended Minimum Installation Clearances for Vertical Units*
1”
Back of unit
Side opposite return air
6” Front if hard piped
Return Air Side
1”
Ducted return
- ‡ Add for duct width
- † Add 2” for 1” fi lter frame/rail or 3” for 2” fi lter frame/rail
Free (open) return - calculate required dimension for a maximum
velocity of 600 fpm
*Field installed accessories (hoses, air cleaners, etc.) may require additional
space.
Top supply air is shown, the same clearances apply to bottom supply air units.