Service manual

Residential Tranquility
®
27 Split (TTS) - 60Hz HFC-410A
Rev.: 8 May, 2014C
38
Geothermal Heating and Cooling
Unit Operating Conditions
Table 15: Water Temperature Change Through Heat
Exchanger
Model GPM
Pressure Drop (psi)
30°F 50°F 70°F 90°F
026
2.3
3.0
3.4
4.5
6.0
0.7
1.1
1.3
2.0
3.1
0.4
0.7
0.9
1.4
2.3
0.4
0.6
0.8
1.2
1.9
0.5
0.7
0.8
1.2
1.8
038
3.0
4.5
6.0
6.8
9.0
1.5
2.6
3.8
4.5
6.9
0.9
1.7
2.7
3.2
5.2
0.8
1.5
2.3
2.7
4.4
0.9
1.5
2.2
2.6
4.1
049
4.5
6.0
6.8
9.0
12.0
0.8
1.3
1.6
2.7
4.6
0.6
1.1
1.4
2.5
4.2
0.5
1.0
1.3
2.3
3.8
0.3
0.9
1.2
2.2
3.5
064
6.0
7.5
9.0
11.3
12.0
15.0
0.9
1.7
2.5
3.7
4.1
6.1
0.2
0.9
1.5
2.6
3.0
4.7
0.2
0.7
1.3
2.3
2.6
4.1
0.3
0.8
1.4
2.3
2.6
4.0
9 - 12
18 - 24
4 - 9
7 - 19
Entering
Water
Temp °F
Water
Flow
GPM
Full Load Cooling - without HWG active Full Load Heating - without HWG active
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Super-
heat
Sub-
cooling
Water Temp
Rise °F
Air Temp
Drop °F
DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Super-
heat
Sub-
cooling
Water Temp
Drop °F
Air Temp
Rise °F
DB
30*
70-80
72-82
75-85
280-300
280-300
280-300
2-7
3-8
3-8
6-11
6-11
6-11
7.3-9.3
6.0-8.0
4.7-6.7
14-20
14-20
14-20
50
3 128-138 216-236 13-18 15-20 18.0-20.0 18-24
105-115
105-115
110-120
310-330
310-330
310-330
4-9
5-10
6-11
6-11
6-11
6-11
10.1-12.1
8.4-10.4
6.6-8.6
19-25
19-25
19-25
70
3
4.5
6
131-141
131-141
131-141
290-310
290-310
275-295
12-17
12-17
12-17
15-20
14-19
13-18
17.3-19.3
14.3-16.3
11.3-13.3
17-23
17-23
17-23
130-140
130-140
132-142
340-360
340-360
340-360
11-16
13-18
15-20
7-12
7-12
8-13
12.8-14.8
10.6-12.6
8.3-10.3
23-28
23-28
23-28
90
3
4.5
6
138-148
138-148
138-148
138-148
138-148
138-148
11-16
11-16
11-16
18-23
16-21
15-20
16.5-18.5
13.6-15.6
10.7-12.7
16-22
16-22
16-22
110
3
4.5
6
142-152
142-152
142-152
480-500
465-485
451-471
10-15
11-16
11-16
19-24
17-22
16-21
15.0-17.0
13.1-15.1
10.3-12.3
16-22
16-22
16-22
*Based on 15% methanol antifreeze solution
Entering
Water
Temp °F
Water
Flow
GPM
Full Load Cooling - without HWG active Full Load Heating - without HWG active
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Super-
heat
Sub-
cooling
Water Temp
Rise °F
Air Temp
Drop °F
DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Super-
heat
Sub-
cooling
Water Temp
Drop °F
Air Temp
Rise °F
DB
30*
67-77
71-81
75-85
274-294
278-298
282-302
8-13
9-14
9-14
1-6
1-6
1-6
8.3-10.3
6.2-8.2
4.0-6.0
15-21
16-22
16-22
50
4.5 125-135 216-236 15-20 13-18 21.0-23.0 17-23
95-105
100-110
104-114
304-324
308-328
311-331
11-16
12-17
12-17
1-6
1-6
1-6
10.7-12.7
7.9-8.9
5.2-7.2
21-27
21-27
21-27
70
4.5
6.75
9
130-140
130-140
129-139
290-310
274-294
256-276
14-19
14-19
14-19
15-20
12-18
9-14
20.4-22.4
15.1-17.1
9.7-11.7
17-23
17-23
17-23
123-133
127-137
132-142
331-351
335-355
340-360
14-19
16-21
17-22
1-6
1-6
1-6
13.5-15.5
10.1-12.1
6.7-8.7
26-32
26-32
26-32
90
4.5
6.75
9
137-147
137-147
137-147
410-430
390-410
370-390
14-19
14-19
13-18
17-22
14-19
11-16
19.6-21.6
14.5-16.5
9.3-11.3
15-21
15-21
15-21
110
4.5
6.75
9
141-151
141-151
141-151
476-496
457-477
439-459
13-18
13-18
13-18
17-22
14-19
11-16
19.2-21.2
14.1-16.1
9.0-11.0
15-21
15-21
15-21
*Based on 15% methanol antifreeze solution
Table 14: Two-Stage HFC-410A Compressor Section
Coax Water Pressure Drop
Table 16a: Size 026 Two-Stage HFC-410A Typical Unit Operating Pressures and Temperatures
Table 16b: Size 038 Two-Stage HFC-410A Typical Unit Operating Pressures and Temperatures