Specifications
TT Series 60Hz - HFC-410A Submittal Data Eng/I-P
ClimateMaster works continually to improve its products. As a result, the design and specications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specic information on the current design and specications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
Revised: 17 July, 2013LC356 - 7
Page ______ of ______
TT Series Nomenclature
B0 2 6 CG 3 0 C L K
4 5 6 7
8
91011121314
026 - E,F,G,H
Unit Size
038 - F,G,H
Return Air
Voltage
Controls
B = Current 026, 049 - 072
C = Current 038
Revision Level
Heat Exchanger & Valve Options
Cabinet Insulation
TT
1 2
TT = Tranquility
®
Two-Stage Scroll
Model Type
V
3
V = Vertical Upflow
Configuration
L = Left Return
R = Right Return
0 = None
ClimaDry
®
reheat coil not coated
Water Circuit Options
2 = HWG (Coil Only)
6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton
7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton
8 = Auto Flow Regulator 2.5 GPM/Ton
9 = Auto Flow Regulator 3.0 GPM/Ton
S
15
S = Standard
Standard
H = Horizontal
D = Vertical Downflow
049 - F,G,H
064 - F,G,H
5 = Secondary Circulating Pump
Supply Air & Motor Option
Option
Supply
Configuration
Motor
K TTV ECM
N TTD ECM
P TTH ECM
W TTH ECM
Top
Down
Back
Straight
072 - F,G,H
Standard
ClimaDry
®
Reheat
Non Coated Air Coil Tin Plated Air Coil
Copper Cupro-Nickel Copper Cupro-Nickel
C
E
N
P
A
D
J
F
Motorized Valve
TSUW
CXM
DXM
CXM w/LON
DXM w/LON
CXM w/MPC
DXM w/MPC
Control w/o Disconnect w/ Disconnect
C
D
L
M
N
P
A
B
E
K
R
S
G = 208-230/60/1
H = 208-230/60/3
E = 265/60/1
F = 460/60/3
Rev.: 14 Jan, 2008D
AVAILABLE
VOLTAGES
OPTION
1
A
J
K
2
C
L
M
3
E
N
P
1” FILTER
RAIL
RANGE
ULTRA
QUIET
2” FILTER
RAIL
1” FILTER
FRAME
2” FILTER
FRAME
4
G
R
S
NO
YES
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
ClimaDry
®
II Option Notes:
1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral.
2. ClimaDry
®
II may not be combined with motorized water valve, internal secondary circulating pump, or automatic ow
regulator options.
3. Unit minimum entering air temperature while in the dehumidication, cooling, or continuous fan modes is 70ºF DB/61ºF WB.
Operation below this minimum may result in nuisance faults.
4. A thermostat with dehumidication mode or thermostat and separate humidistat/dehumidistat is required for activation and
control of ClimaDry
®
II.
5. Downow and 575 volt units are not eligible for ClimaDry
®
II.