Specifications
TT Series 60Hz - HFC-410A Submittal Data Eng/I-P
ClimateMaster works continually to improve its products. As a result, the design and specications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specic information on the current design and specications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
Revised: 17 July, 2013LC356 - 32
Page ______ of ______
TT - Horizontal Dimensional Data
Notes:
1. While clear access to all removable panels is not required,
installer should take care to comply with all building codes
and allow adequate clearance for future eld service.
2. Horizontal units shipped with lter bracket only. This bracket
should be removed for return duct connection
3. Discharge ange and hanger brackets are factory installed.
4. Condensate is 3/4” FPT.
5. Blower service panel requires 2’ service access.
6. Blower service access is through back panel on straight
discharge units or through panel opposite air coil on back
Horizontal
Model
Overall Cabinet
*A
Width
B
Length
C
Height
026
in
cm
22.4
56.8
62.2
158.0
19.3
48.9
038
in
cm
25.4
64.5
71.2
180.8
21.3
54.0
049
in
cm
25.4
64.5
76.2
193.5
21.3
54.0
064 &
072
in
cm
25.4
64.5
81.2
206.2
21.3
54.0
Horizontal
Model
Water Connections
1 2 3 4 5
Loop
In
D
Loop
Out
E
HWG
In
F
HWG
Out
G
H
Water
Loop
FPT
HWG
FPT
026
in
cm
2.1
5.2
10.0
25.4
13.9
35.2
16.9
42.9
3.5
8.9
3/4” 1/2”
038
in
cm
3.4
8.6
10.8
27.5
15.6
39.7
18.9
47.9
3.4
8.6
3/4” 1/2”
049
in
cm
3.4
8.6
10.8
27.5
15.6
39.7
18.9
47.9
3.4
8.6
1” 1/2”
064 &
072
in
cm
3.4
8.6
10.8
27.5
15.6
39.7
18.9
47.9
3.4
8.6
1” 1/2”
Horizontal
Model
Electrical Knockouts
J
1/2”
K
1/2”
L
3/4”
Low
Voltage
External
Pump
Power
Supply
026
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
038
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
049
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
064 &
072
in
cm
3.6
9.2
6.1
15.6
8.6
21.9
discharge units.
Legend:
CAP = Control Access Panel
BSP = Blower Service Panel
CSP = Compressor Access Panel
ASP = Alternative Service Panel
Water Connections -
Units with ClimaDry
®
1 2
Loop
In D
Loop
Out E
2.1
5.2
10.0
25.4
6.01
15.1
13.1
33.4
6.01
15.1
13.1
33.4
6.01
15.1
13.1
33.4
*Does not include air lter supports. Add 2” (5.1cm) when a 1” (25.4mm) lter is used, add 3”
(7.6cm) when a 2” (50.8mm) lter is used.