Specifications

ClimateMaster works continually to improve its products. As a result, the design and speci cations of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for speci c information on the current design and speci cations. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.
Page ______ of ______Rev.: 20 May, 2009BLC291 - 7
CCE Series 60Hz - R22 Submittal Data Eng/I-P
Geothermal Heat Pump Systems
CCE Series Nomenclature
C C E AB0 7 CG S S C S R S
94 5 6
7
8 101112131415
CCE = Console
Power Termination
Revision Level
Voltage
Controls
M = Bottom Return w/UltraQuiet
Cabinet Insulation
L = Bottom Return w/Locking Control Door
Subbase
A = Copper Water Coil w/E-Coated Air Coil
Heat Exchanger Options
C = Copper Water Coil
J = Cupro-Nickel Water Coil w/E-Coated Air Coil
N = Cupro-Nickel Water Coil
R = Right Piping
Piping Connections
L = Left Piping
Standard
D = Bottom Return w/Locking Control Door & UltraQuiet
F = Front Return
S = Bottom Return
B = Front Return w/UltraQuiet
D = 3” Subbase w/Motorized Damper
G = 5” Subbase
S = 3” Subbase
H = 5” Subbase w/Motorized Damper
N = None
V = Copper Water Coil w/E-Coated Air Coil & Extended Range Insulation
E = Copper Water Coil w/Extended Range Insulation
M = Cupro-nickel Water Coil w/E-Coated Air Coil & Extended Range Insulation
F = Cupro-nickel Water Coil w/Extended Range Insulation
1 2 3
S = Standard
None S F M
Motorized Water Valve A G N
Autoflow (2.25 Gpm/Ton) B H P
Autoflow (3.0 Gpm/Ton) C J Q
Motorized Water Valve & Afr (2.25) D K R
Motorized Water Valve & Afr (3.0) E L T
Secondary Circulation Pump U V W
Water Circuit Options
G = Front Return w/Locking Control Door
E = Front Return w/Locking Control Door & UltraQuiet
N = No Cabinet Chassis Only
C = No Cabinet Chassis Only w/UltraQuiet
07
09
12
15
19
B or C = Current Revision
Model Type
Unit Size
A = Field Connected (Hard Wire)
Sweat IPT EPT
A = MCO Unit Mounted Tstat w/CXM
B = MCO Unit Mounted Tstat w/DXM
C = ACO Unit Mounted Tstat w/CXM
D = ACO Unit Mounted Tstat w/DXM
R = Remote Mounted Tstat w/CXM
S = Remote Mounted Tstat w/DXM
L = Remote Mounted w/CXM & LON
M = Remote Mounted w/DXM & LON
N = Remote Mounted w/CXM & MPC
P = Remote Mounted w/DXM & MPC
A = 115/60/1
E = 265/60/1
G = 208-230/60/1
B = 20Amp Plug & Cord
D = Disconnect Switch & 15Amp Fuse
F = Disconnect Switch (Non Fused)
H = 20Amp Plug, Cord, Receptacle,
Disconnect Switch & 15Amp Fuse
K = 20Amp Plug, Cord, Receptacle &
Disconnect Switch (Non Fused)
Digital Display Controls
Rev.: 05/21/09B