Owner`s manual

MULTI-APPLIANCE TOUCH PAD
Controls – Installation / Setu
p
/ Commissionin
g
FAULT CODES FOR HIGH EFFICIENCY, MID EFFICIENCY HEATERS
Code No. Fault Code Diagnosis
00
No Activity There has been no fault codes registered or the
control has not been coded to the unit.
01
Block Flue Check flue cowl installed correctly
02
Pressure Switch fused closed Service Call
03
Combustion air pressure system failure Check combustion fan OK. Service call.
04
Room air over temperature (auto reset) Check Minimum Fan Speed, Duct design
05
Controller electronic malfunction Reset, Service Call
06
Slow closing gas valve Reset, Service Call
07
Ignition failure Check: - igniter works, flame sensor, gas supply. For
forced draft High Efficiency units also check blocked
flue and blocked condensate drain. Service Call
08
Gas Interruption Check gas supply, Flame Sensor, Service Call
09
EEPROM failure Reset, Service Call
11
Missed Transmission Check loom integrity and connections
12
No Communication (Touch Pad Only) Touchpad cannot detect unit – check loom integrity
and connections
15
No recorded fault codes
Bonaire Control Systems
Page 42