Owner`s manual

17
φ65mm
φ65mm
Ø
65
Install the rear panel
. Always mount the rear panel horizontally. As the water drainage pipe at the left, when
adjusting the rear panel, this side should not be too high; the right side should be slightly
high.
Fix the rear panel on the selected
location.
Be sure that the rear panel has
been fixed firmly enough to withstand
the weight of an adult of 60kg,
furthermore, the weight should be
evenly shared by each screw.
Mark on the middle of it
Gradienter
Wall
Wall
Space to
the wall
150mm
above
Space to
the wall
150mm
above
Left
Right
(Rear piping hole)
(Rear piping hole)
Install the piping hole
1Make the piping hole 65in the wall at a slight downward
slant to the outdoor side. At Fig.6.
2
Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Indoor
Outdoor
Wall
pipe
Seal pad
Protection
sleeve pipe
Install the water drainage pipe
For well draining, the drain hose should be
placed at a downward slant.
Do not wrench or bend the drain hose or flood
its end by water.
2
3
When the long drainage hose passing through
indoor, should wrap
the insulation materials.
Wrenched
Bent
Flooded
Connect indoor and outdoor electric wires
1Open the front panel upwardly;
2 Screw off the fixing screw of cover plate
and screw off cover plate (As show in Fig. 7)
3
Put the power connection cable through the
back of indoor unit wire hole and take it ou
4
Connect the blue wire of powe
r
connection
cord to the terminal on “N(1)”, the black one to
“2”, the brown one to " 3",the yellow-green one
earth wire to (As shown in Fig. 8)
5
Put the power connection cable the section,
which with sheath into wire groove, and cov
the cover plate, screw on the fixing screw
tighten the connection wire.
6 Cover the front panel cover.
For the cooling and heating unit, signal control
7
wire can be passed through the connection of
connector and indoor unit, and use the wire clip
that is under the body case, tighten the signal
control wire (As show in Fig. 9)
Power
connection
wire
Wire terminal
cover plate
Fig.7
Fig. 9
Fig. 8
Signal control wire
(Only for cooling and
heating type unit)
Power connection wire
Connector
Wire
clamp
Terminal
board
Blue
Black
Y
Brown
ellow-green
Installation Service- Install indoor unit
Fig.6