Maintenance Instructions ClimaRad 2.0 with electrical radiator
When should you replace the filters?
• With normal use, every 2 years or earlier if the message 'Filter veruild' appears on
the display (for example in homes and offices).
• In the case of intensive use, after 1 year or earlier if the message 'Filter vervuild'
appears on the display (e.g. for care homes and schools).
Go to to view the instruction video.www.climaRad.nl/filtervervanging
Maintenance frequency for filters
Ordering filters
Order new filters at
www.climarad.nl/filters
Replacing air supply filters
1. Switch off the device first by
removing the plug from the
sockets.
2. There is a locking screw at the
bottom of each of the two (or
four) radiator consoles. Remove
these locking screws.
3. Tilt the radiator and, if
required, lock it with an Allen key
or screwdriver.
4. Push the left-hand and right-
hand slide on top of the ClimaRad
inwards and open both covers by
pulling them towards you.
5. Remove the black filter caps on
the left and right.
6. Slide the three new filters in the
unit from the left-hand side. The
old filters will automatically slide
out on the right-hand side.
7. Replace the black filter caps on
the left and right.
8. Close the covers on the left-
hand and right-hand side of the
unit, and slide both latching slides
outwards.
9. Unlock the radiator and tilt it
back. Push the plug back into the
socket and reset the filter hour
counter (by simultaneously pressing
on the + and - on the display for 6
seconds ). The message 'Filter
vervuild' will disappear. Tighten the
locking screws again.
Important: Reset the filter hour counter only if you have replaced
the filters.
left
right
left
right
Slide 3 new filters in
3 old filters will
slide out
left
right
left
right
Press
and
for 6 seconds