Owner's manual

1
www.climacoolcorp.com
Design Features/Bene ts/Options
The ClimaCool Ultimate Chiller Solution
®
, model UCR
provides 30, 50 and 70 ton modules with remote air
cooled condensers which, when combined, can obtain
speci c project turndown and capacity requirements
from 30 to 400 tons per bank.
Environmentally Friendly and Energy E cient
R-410A environmentally friendly, non-ozone
depleting refrigerant
• E ciencies up to 10.9 EER at full load and up to 17.5
EER at part load (IPLV)
Exceeds ASHRAE 90.1 minimum e ciency
requirements
Ease of Service and Installation Advantages
All UCR modules t through 36” doorway and onto
typical freight elevator
Low center of gravity for ease of maneuverability
Base cutouts for pallet jacks or forklifts
Service and maintenance can be performed without
removing module from the chiller bank
Ability to isolate and service individual module
without shutting down the entire system
Ability to produce chilled water even in the event of
a shutdown of one or more refrigerant circuits.
Service friendly access to all major components
Pete’s ports are provided to measure the pressure
di erential across the heat exchangers
Discharge and liquid refrigerant line isolation valves
for remote condenser connection
Internal refrigerant isolation valves for critical
components
Proven Reliability
Redundant operation with UL listed independent
module starter/control panel
Independent refrigeration circuits
Dual Scroll compressors
• Highly e cient dual circuited brazed plate compact
heat exchangers constructed of 316 stainless steel
and rated for 650 psig working refrigerant pressure
Quality and Durability
Heavy gauge G90 galvanized steel base and frame
work
Protective powder coat paint for durable and long
lasting nish
Schedule 40 carbon steel pipe water headers
300 PSI rated grooved coupling connections on
chilled water circuit
Evaporator wrapped with ¾” closed cell insulation
All remote air cooled chillers are pressure-tested,
evacuated and charged with nitrogen
Refrigeration controls include thermostatic
expansion valve, lter drier, sight glass, high and
low pressure controls and safety controls
Integrated CoolLogic Control System
Provide individual module control and chiller bank
integration
Simple two-conductor shielded, daisy chain
connection allowing communication between
modules with minimal eld wiring
Options
Motorized or manual water isolation valves
Hot gas bypass
Sound Attenuation panels
• Pressure di erential ow switch
Manual or automatic strainers