Manual
21
www.climacoolcorp.com
®
SAFETY FIRST!
Keep ngers away from valve opening to avoid getting
caught in the moving parts The electric motor supplies a
sufcient amount of power to cause personal injury Take
precaution when handling
Automatic Timer Flush ATF-EA-15 (optional)
Valve Specications
A Water-resistant Polypropylene Motor Case
B High Torque Motors with Perma-lube Gears
C Open & Close Indicator
D Stainless Steel Ball Valve & Hardware
E Auto Reset Circuit Breaker
F 90 Degree Bidirectional Rotation
G Controller Case
Fig 3
TROUBLESHOOTING: If you require further assistance, please call us at (405) 745-3185.
PROBLEM POSSIBLE CAUSE SOLUTION
• Valve is leaking past ball • Seals damaged or worn out • Install repair kit
• Valve is not stopping at proper • Adjust limit switches
closed position
• Valve stem leaks • Worn stem seals • On metal valves: tighten stem packing
nut 1/2 turn
CAUTION! Over tightening stem nut
could cause drag on motor and trip
internal circuit breaker. May require
repair kit or new valve.
• Valve body leaks • Loose body bolts or excessive operating • Check bolts and observe recommended
pressure ratings
• Defective seals • Install repair kits or new valve
• Valve hard to turn • Swollen seals or product buildup in valve • Check valve for compatibility with
chamber product, may require valve cleaning or
new valve
• Valve bolts too tight • Loosen bolts slightly
• Stem nut too tight • Loosen stem nut slightly
Automatic Timer Flush Package