User Manual
8  INSTALLATION AND OPERATING INSTRUCTIONS
E. PRODUCT SAFETY FEATURES
1.  Automatic Defrosting
To ensure the unit operates and performs as stated, the unit has 
been designed with an Automatic defrost function as frost can be 
produced on the surface of the evaporator in low temperatures.
When the temperature sensor detects the room temperature has 
dropped to 16°C or lower, the Auto Defrost function will start and 
the DEFROST symbol 
will be displayed on the LCD screen. 
The unit compressor will run for 25 minutes on dehumidification 
mode and then the fan will run at high speed in 7 minute cycles to 
defrost the unit.
Note:
 The dehumidification symbol   will disappear.
2.  Protection Of Extremely Low & High Temperature
Unit is built with a room temperature sensor that will automatically 
shut off the unit when the ambient temperature is either less than 
or equal to 0°C or greater than or equal to 40°C. When sensor 
is activated there will be a continuous warning beeper which will 
beep 3 long and 2 short beeps and the corresponding temperature 
(either 0°C or 40°C) will be displayed on LCD screen.
Note:
 Unit will not be operable when sensor is activated, to restart 
unit, unplug unit and restart again.
Note:
 If unit is shut off due to protection of extremely low & high 
temperatures, the unit memory function will not operate, unit will 
reset at default setting.
3.  Failure of Humidity & Temperature Sensor
When the connection wire between the humidity and temperature 
sensor is disconnected, the humidity icon 
 will blink and 
0°C and 0% RH will display on LCD screen. Unit will switch into 
continuous dehumidifying mode.
If the temperature evaporator sensor becomes open circuit or 
short circuit the DEFROST light 
 will start blinking.
Unit will operate in a humidifying and defrosting mode, 
dehumidifying for 20 minutes and then defrosting for 5 minutes.
Note: If the temperature sensor malfunctions, the unit will 
continue to work but at a lower efficiency.
4.  Compressor Protection
If the unit malfunctions during the operation of the unit and the 
compressor fails, the compressor will switch off. Wait a minimum 
of three minutes to reoperate unit.
5.  Memory Function
If the power is cut off during the operation of the appliance, the 
unit will memorise the working mode automatically.
Once power is restored to the unit, the appliance will restart and 
continue working at the last set working mode.