Air Dehumidification System CLI-DH20-E | Installation & Operating Instructions
Congratulations on your purchase of a Cli~Mate Air Dehumidification System. This air dehumidifier is compact and stylish in design, quiet, portable and easy to operate. Unit effectively removes moisture from the air creating a drier, healthier room environment. Note: Please read through the instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference.
SPECIAL PRODUCT INSTRUCTIONS PRODUCT SPECIFICATIONS This appliance is designed for household use only. Do not use this unit outdoors, in wet environments or on wet surfaces. Air Dehumidifier Specifications To achieve best performance; make sure all doors and windows are closed before turning on the unit. System Specifications CLI-DH20-E Air Dehumidification System Dehumidification 20 Litres/day The appliance air vents and air grilles must not be obstructed at any time.
OPERATION CONDITIONS AND SAFETY PRECAUTIONS Read all instructions carefully. • All components need to be installed in accordance with the user manual instructions for correct performance of unit. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• If unit ever tips or falls over when water reservoir is full, immediately unplug the power cord. Ensure unit is dried thoroughly before operation of the unit. • Do not put fingers or other objects in any openings of the unit.
A. COMPONENT IDENTIFICATION AND CHECK LIST A. Dry Air Outlet A B. Control Panel C. LCD Display D. Handle E. Humid Air inlet F. Air Filter C B D G. Continuous Drainage Hose* E H. Continuous Drainage Outlet (For hose connection) I. F Water Reservoir H I G * Continuous drainage hose is an extra drainage option; hose does not need to be connected if using the water reservoir to catch condensed water.
B. CONTROL PANEL & KEY PADS C. LCD DISPLAY ICONS 1 2 3 M od e Timer Settings S wing 11 4 10 POWER Turns unit ON/OFF. 5 9 MODE Allows selection of desired working mode, the corresponding indicator light will illuminate. 6 8 7 SETTING Allows selection of the desired running mode (High (H), Low (L)) and ambient relative humidity ratios. 1. Automatic Dehumidifying 7. Dehumidifying 2. RH Settings 8. Timer TIMER To set automatic ON/OFF timer at 1 to 24 hour settings. 3. Wind Speed 4.
D. OPERATION INSTRUCTIONS 1. Plug unit into power socket, unit will beep twice. to turn unit on. The dry air outlet 2. Press POWER button air deflector will open and the blue backlight will illuminate and turn off after 15 seconds. The LCD display will show the working mode, status of unit, ambient humidity and temperature. Note: The dehumidification setting is automatically set on continuous and default fan speed is set at High (H). Note: The dry air outlet air deflector will close when unit is turned off.
8. To select ON/OFF timer. To set automatic OFF timer, press TIMER button when unit is powered ON; select the desired running time, 1 to 24 hours. Unit will automatically switch OFF once selected OFF time duration has lapsed. The screen will display time elapsed and remaining running time. To set automatic ON timer, press TIMER button when unit is powered OFF or on standby mode, select the desired time for unit to start operating in 1 to 24 hours.
E. PRODUCT SAFETY FEATURES 3. Failure of Humidity & Temperature Sensor 1. Automatic Defrosting When the connection wire between the humidity and temperature sensor is disconnected, the humidity icon will blink and 0°C and 0% RH will display on LCD screen. Unit will switch into continuous dehumidifying mode. To ensure the unit operates and performs as stated, the unit has been designed with an Automatic defrost function as frost can be produced on the surface of the evaporator in low temperatures.
Note: If the ON/OFF timer has been set and activated, the unit will restart at default operating mode, not at previous set mode. Note: If power supply is cut off due to one of the safety features being activated, the unit will not restart at previous set mode but at the default mode. G. MAINTENANCE AND REPAIR Before carrying out any maintenance or cleaning of the unit, make sure that the power to the unit is turned off and power cord is removed from the power socket.
H. UNIT NOT USED FOR PROLONGED PERIODS If not using the unit for a prolonged period, switch off and unplug the unit, empty the water reservoir, and allow minimum of two days for unit to dry before packing away. Keep unit in a dry and ventilated place. Repair: If the unit or power cord is damaged, stop using immediately and bring the unit to authorised service center for repair, never attempt to dismantle, repair or modify the unit by yourself. Warranty will be null and void.
I. TROUBLE SHOOTING BEFORE YOU CALL FOR SERVICE PLEASE REVIEW THE TROUBLE SHOOTING TIPS FIRST. Problem Possible Causes What To Do 1. Check connection to wall socket 1. Unit is not plugged into wall socket No Power 2. One of the units product safety features has been activated. 1. Unit is not plugged into wall socket No Air 2. Humidity ratio (if set) has been reached. 3. Air outlet blocked 4. Water Reservoir is full 1. Air ventilation around unit not sufficient Unit Overheating 2.
Problem Loud Noise Possible Causes What To Do 1. Unit not on a level flat surface 1. Reposition or relocate unit onto a flat surface. 2. Faulty internals 2. Call customer care. 1. Water reservoir not installed correctly Water at Base of Unit 2. Continuous drainage hose not connected to spigot properly. 1. Reinstall water reservoir 3. Continuous drainage hose outlet not over water drain 3. Check hose outlet is flowing into water drain. 1. Water Reservoir is Full Beeping Alarm Noise 2.
Your Aquaport 12 Month Repair or Replacement Warranty Conditions Of This Warranty: quaport warrants this appliance to the first purchaser and subject to A the stated conditions: 1. This product has been fully installed in accordance with the user manual installation instructions. Warranty covers any defects in material or workmanship in the manufactured product within the first twelve months from the date of purchase. 2.
CUSTOMER HOTLINE: 1300 764 325 Aquaport Corporation Pty Ltd PO Box 81 Findon SA 5023 Australia Telephone: 1300 764 325 Facsimile: 08 8354 0722 Email: aquaport@aquaport.com.au Web: www.aquaport.com.