CHECKING THE CABLING
If the battery pack is functioning properly, check if the measured voltage across pins 1 to 5 of connector CN4 on the
power board (Fig. 4-3) is the same as the voltage measured for the battery pack. If the measured voltages are not the
same, check if the fuse on the power board has been damaged.
CHECKING THE SYSTEM BOARD
Automatic short-circuit protection
may have been activated by a short circuit occurring in the system. The system cannot
be turned on with automatic short-circuit protection activated. If you detect a short circuit in the system board, fix the
problem accordingly.