Repair manual
STEP
TEST
RESULT
REMEDY
16. Reconnect one lead of the ohmmeter to the COM wire at the
control board and connect the other ohmmeter lead to
generator ground. Does the ohmmeter read less than 10
ohms?
Yes
No
Reconnect HI LOW & COM wires
at control board only. Go to Step #17.
Replace probe wiring
17. Reconnect the ohmmeter across the LOW terminal at the
sensing probe & generator ground. Does the ohmmeter read
greater than 100,000 ohms?
Yes
No
Go to Step #18
Replace probe assembly
18. Reconnect the ohmmeter across the HI terminal at the sens-
ing probe & generator ground. Does the ohmmeter read
greater than 100,000 ohms?
Yes
No
Go to Step #19
Replace probe assembly
19. Remove probe and check for scale buildup on or across
probes. Replace probe assembly as required.