Repair manual

STEP TEST RESULT REMEDY
9.
Remove the short from the HI and COM terminals on the
control board. Does the AC line voltage between WF
and L2 stay at 0 vac for about five seconds, then jump to
120 vac?
Yes
No
Reconnect El & COM wires and go to Step
#10
Replace water level control P/N 23198
10. Drain all water form the gen
erator. Disconnect the wires
from the LO, HI, & COM terminals at the control board.
Yes Go to Step #12
Connect an Ohmmeter across the LO and COM vires
leading to the generator. Does the Ohmmeter read
greater than 100,000 ohms?
No Go to Step #11
11. Disconnect the LO wire at the water sensing probe on
the generator. Does the Ohmmeter connected in the
previous step now read greater than 100,000 ohms?
Yes
No
Go to Step #12
Replace probe wiring
12. Reconnect the ohmmeter across each end of the
disconnected
Yes Go to Step #13
LO wire. Does the ohmmeter read less than 10 ohms?
No Replace wire
13. Connect an ohmmeter across the HI and COM wires
leading to the generator. Does the ohmmeter read
greater than 100,000 ohms?
Yes
No
Go to Step #15
Go to Step #14
14.
Disconnect the HI wire at the water sensing probe on the
generator. Does the ohmmeter connected in the
previous step now read greater than 100,000 ohms?
Yes
No
Replace probe wiring
Go to Step #16
15. Reconnect the ohmmeter across each end of the
disconnected HI wire. Does the ohmmeter read less than
10 ohms?
Yes
No
Go to Step #16
Replace probe wiring